Troubleshooting - Vinten FE-165 Light User Manual

Robotic elevation unit
Table of Contents

Advertisement

Fault
The FE-165 is not operating.
The FE-165 is connected to the AC power
source and switched on, but not operating and
the power switch is not illuminated.
Intermittent or no communications with the FE-
165.
The AC power source has failed or is
unavailable and the elevation column is stuck
in an elevated position.
LED Indicators
Data
Genlock
Status
LED
LED
Factory
Reset
Error
Detection
Check that the power switch is ON and illuminated.
Check that the AC power source is connected and secured.
Check that a network connection has been made with the
Ethernet cable.
Check the fuse and replace as necessary with the correct
type and rating.
Check the Ethernet cable.
Check the Ethernet cable is CAT5E FTP.
Operate the column release knob to enable the elevation
column to be safely lowered.
The FE-165 is currently being reset by the control system.
The emergency stop button may have been activated. See the section Using the Emergency Stop
Button on page 26.
The FE-165 has detected an error. Try power cycling the FE-165 and resetting using the control system.
Check
Comments

Troubleshooting

Comments
See the section Powering
Up on page 23.
See the section Power
Connections on page 21.
See the section System
Connections on page 20.
See the section Changing
the Fuse on page 30.
If possible, try using another
Ethernet cable.
See the section Using the
Column Release Knob on
page 27.