Troubleshooting; Default Settings; Aps Scanner Function - Vinten V4109-0001 User Manual

Aps scanner
Table of Contents

Advertisement

Default Settings

The following table lists the factory default setting values for the APS scanner.
Landmark Detection
Cylindrical Reflector Size
Flat Reflector Size
Action Radius (Min)
Action Radius (Max)
N closest reflectors

APS Scanner Function

Fault
The APS scanner is switched on,
but the power switch and LCD
display are not illuminated and the
laser scanner head is not rotating.
The pedestal is not maintaining
consistent and accurate absolute
positioning during normal
operation.
Default Value
76 mm
Reflector Threshold
75 mm
Sliding Mean Depth
500 mm
Radius of landmark detection window at (distLow)
70000 mm
Radius of landmark detection window at (distHigh)
0
Check that all the interconnections on the APS scanner are
secure.
Check that the Fusion pedestal is connected to the power source
supply and switched on.
Check that the APS scanner has a clear view of the reflective
target positions (no obstructions) and they are in the correct
installation positions.
The APS scanner needs contact with at least three reflective
targets.
Repeat the landmark map scan procedure, appending any new
or moved reflective targets to the current landmark map.
Positioning
Check

Troubleshooting

Default Value
50%
1
300 mm at 500 mm distance
300 mm at 70000 mm distance
Comments
See Electrical Connections on
page 7.
See the APS Reflective Targets
Installation Guide, publication part
No. V4109-4981.
See Adding Additional Targets to a
Landmark Map on page 12.