Specifications
Fuel Type
Maximum Input (Btuh / kW)
Minimum Input (Btuh / kW)
Inlet Gas Supply Pressure Acceptable
at the Inlet of the Heater for Purpose of
Input Adjustment (In. W.C. / kPa)
Burner Manifold Pressure
(In. W.C. / kPa)
Fuel Consumption Per Hour
Motor Characteristics
Blower Speed
Electrical Supply (Volts/Hz/Phase)
Amp Draw
Dimensions L x W x H (Inches/cm)
Minimum Safe Distances from Nearest
Combustible Material (Feet/Meters)
Minimum Distance from Fuel Supply (ft./m)
Minimum Operating Ambient Temperature
Net Weight (lbs./kg)
Certification - OMNI Test Laboratory
Owner's Manual •
MAX.
MIN.
MAX.
MIN.
MAX.
MIN.
Continuous
Top
Sides
Back
Blower
Outlet
Commander Ductable Make-Up Air Heater
CM500
Propane Gas
Natural Gas
500,000 / 146.5
100,000 / 29.3
3.3 / 0.82
8.0 / 1.99
0.9 / 0.22
1.1 / 0.27
23.2 lbs. /
500 cu. ft. /
10.5 kg
14.2 m³
5.8 lbs. /
100 cu. ft. /
2.6 kg
2.8 m³
1 H.P. (0.75 kW),
120-240V, Thermally
Protected, Ball Bearing
1725 RPM
120 / 60 / 1
11.1
61.8 x 32.0 x 52.1 /
157.0 x 81.3 x 132.3
Propane - U.S.: 6/1.83, Canada: 10/3.05
Natural Gas - N/A
-20°F / -29°C
500 / 226.8
ANSI Z83.7•CSA 2.14 (2017)
CM1000
Propane Gas
Natural Gas
1,000,000 / 293
200,000 / 58.6
13.8 / 3.4
13.8 / 3.4
3.3 / 0.82
8.0 / 1.99
0.7 / 0.17
0.8 / 0.20
46.4 lbs. /
1000 cu. ft. /
21.0 kg
28.3 m³
9.3 lbs /
200 cu. ft. /
4.2 kg
2 H.P. (1.5 kW),
208-230V, Thermally
Protected, Ball Bearing
240 / 60 / 1
8.5
72.4 x 35.0 x 56.1 /
183.9 x 88.9 x 142.3
1 / 0.3
1 / 0.3
1 / 0.3
6 /1.83
650 / 294.8
ANSI Z83.7 (2017)
5.7 m³