This heater has been designed and developed as a ductable indirect-fired forced air
construction heater with application for the temporary heating of buildings under
construction, alteration, or repair.
Additionally, this heater can be used for tent heating applications with temporary
human occupancy. If you are considering using this heater for any application other
than these intended uses, then please contact L.B. White Co. at (800) 345-7200.
Director
MODELS
OUTPUT (Btuh)
CP100AKI
100,000
CP300AKI
230,000
Construction Heater
FUEL
Kerosene
#1 Diesel/
Fuel Oil
150-24287-A

Advertisement

Table of Contents
loading

Summary of Contents for L.B. White Director CP100AKI

  • Page 1 Your new L.B. White heater incorporates the benefits from the most experienced manufacturer of heating products using state-of-the-art technology. We, at L.B. White, thank you for your confidence in our products and welcome any suggestions or comments you may have...call us, toll-free, at (800) 345-7200.
  • Page 2 Only properly-trained service people should repair or install this heater. Save this Owner’s Manual for future use and reference. Owner’s Manuals and replacement labels are available at no charge. For assistance, contact L.B. White at 800-345-7200. WARNING WARNING Fire and Explosion Hazard...
  • Page 3: Table Of Contents

    Have your qualified installer review this manual with you so that you fully understand the heater and how it The L.B. White Co., Inc. has a policy of continuous product functions. improvement. It reserves the right to change specifications...
  • Page 4: Heater Specifications

    Heater Specifications M M o o d d e e l l CP100AKI C C P300AKI SPECIFICATIONS K K e e r r o o s s e e n n e e , , # # 1 1 D D i i e e s s e e l l / / F F u u e e l l O O i i l l Fuel Type Max Input (BTUH) 105,000...
  • Page 5: Safety Precautions

    Manual, etc., that is provided with each heater. c) All flame shall be extinguished and the heater 2. All installations and applications of L.B. White heaters allowed to cool prior to fueling. must meet all relevant local, state and national codes.
  • Page 6: Installation Instructions

    18. Never move, handle, refuel, or ser vice a hot, fire retardant nature. These enclosure materials shall operating, or plugged-in heater. be securely fastened to prevent them from igniting or from upsetting the heater due to wind action. 19. Never attach duct work to rear of heater. 22.
  • Page 7 FIG. 2 VENTING TO EXISTING CHIMNEY FIG. 3 VENTING TO OUTSIDE THROUGH WALL Minimal 4 ft. 1) Anti-wind device provided with the heater B) Minimal 4 ft. 2) Horizontal crossing with minimal upside angle pitch of 5º C) The shortest 3) Chimney 51 in.
  • Page 8: Operation Instructions

    Operation Instructions THEORY OF OPERATION T T H H E E F F U U E E L L S S Y Y S S T T E E M M T T H H E E I I G G N N I I T T I I O O N N S S Y Y S S T T E E M M The motor turns the fuel pump.
  • Page 9: Connecting Thermostat

    CONNECTING THERMOSTAT (Optional Accessory - Part #24219) To connect a thermostat refer to the following instructions: e) Route thermostat cord set through strain relief, support rings, and into plug. Thread strain relief a) Pull latch away from thermostat plug on control into plug housing.
  • Page 10: Start-Up Instructions

    Start-Up Instructions Follow all ventilation and safety information. might be necessary to renew the starting procedure once or twice by depressing the “Reset” button. To Check that your electrical supply to the heater facilitate starting, remove the canister bottom from conforms to the data plate, before heater operation is the pump’s fuel filter and fill with fuel.
  • Page 11: Cleaning And Storage Instructions

    Cleaning and Storage Instructions WARNING Fire, B B urn, a a nd E E xplosion H H azard This heater contains electrical and mechanical components in the fuel management, and safety systems. Such components may become inoperative or fail due to dust, dirt, wear and aging. Periodic cleaning and inspection as well as proper maintenance are essential to avoid serious injury or property damage.
  • Page 12: Maintenance Instructions

    Maintenance Instructions 1. The area surrounding the heater shall be kept clear or health hazard. and free from combustible materials, gasoline, and other flammable vapors and liquids. 6. Refer to the following preventative maintenance schedule: 2. Check all wiring associated terminals and electrical Item Maintenance S S chedule components within the heater for corrosion, frayed or...
  • Page 13: Setting For High Altitude

    Setting for High Altitude The heater may be operated at dif ferent altitudes. Although there are not any parts that need to be changed, AIR OPENING SETTING you must set the air adjustment ring at the burner to ALTITUDE compensate for the change in altitude. DIRECTOR DIRECTOR (FEET)
  • Page 14: Troubleshooting Information

    Troubleshooting Information READ THIS ENTIRE SECTION BEFORE BEGINNING TEST E E QUIPMENT R R EQUIRED TO TROUBLESHOOT PROBLEMS. The following pieces of test equipment will be required to troubleshoot this system with minimal time and effort. WARNING • • D D i i g g i i t t a a l l M M u u l l t t i i m m e e t t e e r r - for measuring AC voltage and resistance. This heater can start at any time.
  • Page 15: Electrical Connection And Ladder Diagram

    Electrical Connection and Ladder Diagram 115/60/1 FUSE 10 11 12 HEATED FILTER INDICATOR LIGHT RELAY SWITCH THERMOSTAT PLUG 9 10 11 12 IGNITION CONTROL BOARD...
  • Page 16: Parts Identification

    Parts Identification PARTS SCHEMATIC...
  • Page 17: Parts List

    PARTS LIST Part Number Item Description Director 100 Director 300 Handle 24712 24290 Leg, Support Frame 24713 24291 Plug 24292 Axle 24714 24293 Wheel 24602 24294 Wheel Holder 24603 24295 Fuel Tank 24604 24296 Drain Plug w/ Seal 24251 Drain Plug Seal 24298 Fuel Cap 24252...
  • Page 18 PARTS LIST (cont.) Part Number Item Description Director 100 Director 300 Seal, Filter, Housing 24330 Seal, Filter, Upper 24331 Oil Filter 24265 Filter Housing 24266 Fan Switch, Thermostat 24724 24267 Limit Switch 24268 Electrode 24269 Ignition Boot 24332 Oil Supply Line, Ø 4mm 24610 24333 Pump...
  • Page 19: Warranty Policy

    12 months from date of shipment from L B. White. found to be defective, L.B. White Co., Inc. will at its option, repair or replace the defective part or heater, with a new...