Owner's Manual and Instructions
Congratulations!
You have purchased the finest kerosene portable forced air construction heater available.
Your new L.B. White heater incorporates the benefits from the most experienced
manufacturer of heating products using state-of-the-art technology.
We, at L.B. White, thank you for your confidence in our products and welcome any
suggestions or comments you may have...call us, toll-free, at (800) 345-7200.
he requirements of Standard ANSI A10.10-1998, CAN/CSA B140.87 and CSA
ATTENTION ALL USERS
This heater has been tested and evaluated by C.S.A. International in accordance with
the requirements of Standard UL733 and ANSI A10.10-1998, CAN/CSA B140.0-03
and CSA B140.8 - 1967 and is listed and approved as a Kerosene forced-air
construction heater with application for the temporary heating of buildings under
construction, alteration, or repair. If you are considering using this product for any
application other than its intended use, then please contactthe L.B. White Co., Inc.
Tradesman Kerosene Heaters
MODELS
OUTPUT (BTUH)
CP125CK
125,000
CP170CK
170,000
CP210CK
210,000
Certification by:
FUEL
1-K
Kerosene
150-28271

Advertisement

Table of Contents
loading

Summary of Contents for L.B. White CP125CK

  • Page 1 Owner's Manual and Instructions Tradesman Kerosene Heaters MODELS OUTPUT (BTUH) FUEL CP125CK 125,000 CP170CK 170,000 Kerosene CP210CK 210,000 Certification by: Congratulations! You have purchased the finest kerosene portable forced air construction heater available. Your new L.B. White heater incorporates the benefits from the most experienced manufacturer of heating products using state-of-the-art technology.
  • Page 3: Table Of Contents

    Parts Schematic (CP125CK & CP170CK) ........
  • Page 4: Heater Specifications

    Heater Specifications Model SPECIFICATIONS C C P P 1 1 2 2 5 5 CK K C C P P 1 1 7 7 0 0 CK K C C P P 2 2 1 1 0 0 CK K Fuel Type 1-K, Kerosene 125,000...
  • Page 5: Hazard Definitions

    DANGER Indicates an imminently hazardous situation which, if not avoided WILL result in death or serious injury. WARNING Indicates a potentially hazardous situation which, if not avoided, COULD result in death or serious injury. CAUTION Indicates a potentially hazardous situation which, if not avoided, MAY result in minor or moderate injury.
  • Page 6 WARNING WARNING Risk of CO Poisoning! Risk of Burns/Fire/Explosion! U U se this heater only in well ventilation areas. Provide proper Keep all combustible materials away from this heater. ventilation. See heater specifications (page 4). Minimum Clearances Outlet 8 feet (250 cm) Never use this heater in living or sleeping areas.
  • Page 7: Heater Specifications

    Installation and Assembly Instructions HEATER SPECIFICATIONS Product Features Introduction Electric Outlet Please read this USER’S MANUAL carefully. It will show you Handle Front how to assemble, maintain and operate this heater safely and efficiently to obtain the full benefits of its many Hot Air Outlet features.
  • Page 8: Assembly

    - Over inflation may lead to serious injury - NEVER fill tires using an air compressor. A manual pump is recommended WARNING Fire or explosion hazard! Do not operate heater without support frame fully assembled to tank. Model CP125CK CP170CK CP210CK Wheel Support Frame Wheels Front-Handle Rear-Handle...
  • Page 9: Operation

    Internal Shut-off Temp. Reset Temp. heat. +/-10 Degrees +/-10 Degrees NEVER use kerosene that has been stored from one season to the next. Kerosene deteriorates over time. OLD CP125CK/CP170CK F/110 F/90 KEROSENE WILL NOT BURN PROPERLY IN THIS HEATER. CP210CK F/90 F/60 Use 1-K kerosene in this heater.
  • Page 10: Fueling Your Heater

    OPERATION (cont.) FUELING YOUR HEATER TO SHUT DOWN HEATER Never fill the heater fuel tank in the living space: fill the Turn switch to “OFF” and unplug power cord. tank outdoors. Lamp Room Temp. Display Do not overfill your heater and be sure heater is level. Power/Reset Switch WARNING...
  • Page 11: Longterm Storage Of Your Heater

    OPERATION (cont.) LONG-TERM STORAGE OF YOUR HEATER IMPORTANT: Do not store kerosene over summer for use during next heating FUEL TANK DRAIN season. Using old fuel may damage heater. 1. Remove drain bolt from bottom of fuel tank . See Figure 8.
  • Page 12: Maintenance

    MAINTENANCE USE ORIGINAL EQUIPMENT REPLACE MENT PARTS. Use of third-party or other alternate components will void warranty and may cause unsafe operating conditions. AIR OUTPUT FILTER, LINT FILTER WARNING Air Output Filter Fire or explosion hazard! Never service heater while it is plugged in or while hot! End Filter Cover Screw FUEL TANK...
  • Page 13: Nozzle

    (For Model CP210CK Only) CLEAN NOZZLE AS NEEDED - Remove upper shell (See Air Intake Filter, page 12). (For Models CP125CK and CP170CK only) - Remove fan blade (See Fan Blades). - Remove upper shell (See Air Intake Filter, page 12).
  • Page 14: Spark Plug

    F F i i g g u u r r e e 1 1 4 4 – – S S p p a a r r k k P P l l u u g g R R e e p p l l a a c c e e m m e e n n t t (For Models CP125CK and CP170CK only) - Remove upper shell (See Air Intake Filter, page 12).
  • Page 15: Fuel Filter

    - Turn relief valve clockwise to increase pressure. - Turn relief valve counterclockwise to decrease pressure. - Set pump pressure to correct pressure for each model. - Stop heater (see “Operation”, page 10). Model Pump Pressure CP125CK 5.5 PSI CP170CK 6.5 PSI CP210CK 8.5 PSI NOTE: USE ONLY ORIGINAL EQUIPMENT REPLACEMENT PARTS.
  • Page 16: Replacing Fuse

    MAINTENANCE (cont.) REPLACING FUSE Fuse Holder Fuse Screw Side Cover Power Switch Switch Wire Figure 19 – Replacing Fuse NOTE: The heater is fuse protected. If your heater fails to ignite, DO NOT RETURN YOUR HEATER TO THE STORE. Please follow the simple instructions below to inspect and change the fuse.
  • Page 17: Wiring Diagram

    GREEN THERMOSTAT CN2(AC2)/ (TEMP. CONTROL) EARTH CN1(AC1)/ BLUE BLACK ROOM I/G WIRE PHOTO MODEL CAPACITOR BLUE BLACK SENSOR CELL COLOR BLACK CP125CK 20uF/350VAC WHITE BLACK POWER LIMIT FUSE CP170CK 20uF/350VAC BLUE SWITCH CONTROL 8A/125VAC POWER BLACK BLACK CP210CK 20uF/350VAC PLUG...
  • Page 18: Troubleshooting

    Troubleshooting Chart S S ymptom Possible Cause(s) Corrective Action 1. Wrong pump pressure 1. See Pump Pressure Adjustment, page 15 Heater ignites but MAIN PCB assembly shuts heater off after a 2. Dirty Air Output, Air Intake or Lint Filter 2.
  • Page 19: Parts Identification

    Parts Identification PARTS SCHEMATIC (CP125CK & CP170CK) For Repair Parts, call 1-800-345-7200 Please provide following information: -Model number -Serial number (if any) -Part description and number as shown in parts list F F i i g g u u r r e e 2 2 2 2 – – R R e e p p a a i i r r P P a a r r t t s s I I l l l l u u s s t t r r a a t t i i o o n n f f o o r r P P o o r r t t a a b b l l e e O O i i l l - - F F i i r r e e d d H H e e a a t t e e r r s s M M o o d d e e l l s s C C P P 1 1 2 2 5 5 CK K , , C C P P 1 1 7 7 0 0 CK K...
  • Page 20: Parts List (Cp125Ck & Cp170Ck)

    PARTS LIST (CP125CK & CP170CK) Reference Part Number for Models: Number Description C C P P 1 1 2 2 5 5 CK K C C P P 1 1 7 7 0 0 CK K Fuel Tank Assembly 572707...
  • Page 21: Parts Schematic (Cp210Ck)

    Parts Identification PARTS SCHEMATIC (CP210CK) For Repair Parts, call 1-800-345-7200 Please provide following information: -Model number -Serial number (if any) -Part description and number as shown in parts list F F i i g g u u r r e e 2 2 3 3 – Repair Parts Illustration for Portable Oil-Fired Heater (Model CP210CK) 4 21...
  • Page 22: Parts List (Cp210Ck)

    PARTS LIST (CP210CK) Reference Part Number for Models: Number Description CP210CK Fuel Tank Assembly 572721 Fuel Gauge 572151 Fuel Cap 572157 Panel Right Side Assembly 572264 Power Switch 572251 Thermostat Wire 572149 Drain Plug 572450 Power Cord 572160 Panel Left Side Assembly 572262 Ignition Transformer 572246...
  • Page 23: Parts Schematic (Handles/Wheels)

    -Part description and number as shown in parts list F F i i g g u u r r e e 2 2 4 4 – Repair Parts Illustration for Models CP125CK, CP170CK, CP210CK Replacement Parts List for Models CP125CK, CP170CK, CP210CK Ref.
  • Page 24: Warranty Information

    The remedies set forth above are the sole and L. B. White heater are free from defects both in material and exclusive remedies available hereunder. L.B. White will not workmanship for 12 months from the date of purchase by be liable for any incidental or consequential damages the end user.

This manual is also suitable for:

Cp170ckCp210ck

Table of Contents