Appendix C: Specifications; Iq8 Commercial Microinverters - enphase IQ8 Design Manual

Commercial microinverter grid-tied pv system
Table of Contents

Advertisement

o
If the number of microinverters connected to C1, C2, and C3 types of
connectors is not the same, refer to local AHJ rules for acceptable phase
imbalance across the system.
o
Enphase Installer App provides phase connection details during the array
builder or commissioning process. Validate your imbalance expectations
through the Enphase Installer App.
o
Enphase Installer App shall be able to share a consolidated report of all microinverters
with each phase connection.

10 Appendix C: Specifications

10.1 IQ8 Commercial Microinverters

INPUT DATA (DC)
Commonly used modules for pairing 1
Module compatibility 1
Maximum input DC voltage
Peak power tracking voltage
Operating range
Min/Max start voltage
Max DC short circuit current
(module Isc)
Overvoltage class DC ports
DC port back feed current
68
Figure 47: Enphase Installer App phase connection
IQ8P-3P-72-2-US
380 W-640 W
54-cell/108 half-cell, 60-cell/120
half-cell, 66-cell/132 half-cells, and
72- cell/144 half-cell
63 V
35.5-53 V
16-63 V
22/65 V
20 A
II
0 A
© 2023 Enphase Energy Inc. All rights reserved.
IQ8 Commercial Microinverter grid-tied PV system
IQ8H-3P-72-2-US
320 W-540 W
54-cell/108 half-cell, 60-cell/120
half-cell, 66-cell/132 half-cells, and
72-cell/144 half-cell
63 V
28.5-45 V
16-63 V
22/65 V
20 A
II
0 A
November 2023