DC Cable safety
NOTES:
9
When installing the QD Cable and accessories, adhere to the following:
Do not expose the QD Terminator cap or cable connections to directed,
pressurized liquid (water jets, etc.).
Do not expose the QD Terminator or QD Cable to continuous immersion.
Do not expose the QD Terminator cap or QD Cable connections to continuous
tension (e.g., tension due to pulling or bending the cable near the connection).
Use only compatible QD connectors.
Do not allow contamination or debris in the connectors.
Use the QD Terminator cap and cable connections only when all parts are
present and intact.
Do not install or use in potentially explosive environments.
Do not allow the QD Terminator to come into contact with an open flame.
Fit the QD Terminator cap using only the prescribed tools and in the prescribed
manner.
Use only the QD Terminator to seal the conductor end of the QD Cable; no
other method is allowed.
Ensure proper routing of PV module DC cable using the clips to prevent the
leads from resting on the roof. Do not wrap excess DC cable around the
microinverter.
Avoid direct exposure to sunlight.
Avoid sharp edges on racking.
Avoid cable contacting rough surfaces or moving parts within the racking
system.
Avoid overly tight bending radii. The minimum bend radii for the DC cable is 8
times cable outer diameter.
Avoid overly tight-sized cable clips for routing.
© 2023 Enphase Energy Inc. All rights reserved.
IQ8 Commercial Microinverter grid-tied PV system
November 2023
USG-00026-1.0