enphase IQ8 Design Manual page 49

Commercial microinverter grid-tied pv system
Table of Contents

Advertisement

Step 5: Configure Production and Consumption CTs using the meter wizard
A. Verify that the configuration matches what is installed (solar + load or load only).
B. Enable the meters by verifying the readings by going through the meter wizard (required).
C. While in the production meter wizard, switch OFF the PV breakers as instructed to make sure
the readings go to zero before enabling.
D. While in the consumption meter wizard, turn ON the PV and a known load in the home to
confirm consumption rises as expected, and select the meter location (solar + load)s.
E. To commission the CTs, see
configure production and consumption
49
How do I use the meter wizard in the Enphase Installer App to
CTs?.