Control The Space And Airflow Around The Cabinet - ABB InCharge Terra 184 Manual

All-in-one 90kw dc fast charger
Hide thumbs Also See for InCharge Terra 184:
Table of Contents

Advertisement

Procedure
1. Select a suitable site:
a. Make sure that the space and the airflow around the cabinet is sufficient.
b. Design the site so that the charge cables are of sufficient length for
c. Make sure that the site complies with the relevant usability standards, such
2. If the local rules require the installation of an external residual-current device,
install an external residual-current device. Refer to section 3.9.
3. Prepare the cables:
4. If you use an Ethernet cable, make sure that the internet connection is available
for an approved service engineer and the network operating center of the
manufacturer.
5. Make sure that the cable slack is sufficient to guide the cables in the cabinet.
Refer to section 10.12.9.
6. Prepare the foundation for the cabinet. Refer to section 5.3.
5.2.2

Control the space and airflow around the cabinet

Preliminary requirements
Procedure
1. Make sure that the floor space is in accordance with the requirements. Refer to
section 10.12.5.
2. Make sure that the air flow inlet and outlet cannot get blocked. Think of snow or
objects.
9AKK108466A3703-EN | 001
Refer to section 5.2.2.
connection at the inlet for the EV charge cables on the EVs. For the length of
the charge cables, refer to section 10.12.1.
as ADA and DIN 18040:
Limit the curb heights.
Take into account the limited reach of a wheelchair user. Refer to section
10.12.10.
AC input wire. Refer to section 10.16.
PE wire. The diameter depends on the length, method of installation and
other factors. Make sure that the PE wire is in accordance with the safety
instructions. Refer to section 2.8.
Ethernet cable, if no wireless 2G/3G/4G signal is available. Refer to section
10.13. Contact the manufacturer if you require a specific configuration. Refer
to section 1.12.
Note:
The cables enter the cabinet from the bottom.
Take into account the maximum opening of the cable inlet when
you prepare the cables. Refer to section 10.12.1.