Wire Specifications; Wiring Diagram For The Tilt Sensors - ABB InCharge Terra 184 Manual

All-in-one 90kw dc fast charger
Hide thumbs Also See for InCharge Terra 184:
Table of Contents

Advertisement

10.10.2

Wire specifications

Tilt sensor cables
Number of cores
Diameter of cores
Diameter outside
Conductor
Insulation
Minimum test
Strip length
Voltage rating
Shielded wire
10.10.3

Wiring diagram for the tilt sensors

A
B
C
Parameter
White cable
Yellow cable
9AKK108466A3703-EN | 001
A
V+
GND
NC
COM
E
EVSE
Twisted wire
External power supply
Specifications
One twisted pair (total of two cores)
18 AWG
5 to 10 mm (0.20 to 0.39 in)
Fine strand copper wire
PVC or other material that is serviceable
for outdoor use and UV-protected
1.5 kV
11 mm (0.43 in)
600 V
Not required
B
B
D
Upstream breaker in the power
distribution board
E
Scope of supply by the
manufacturer
Specification
Signal description
TB label
24 V DC
V
0 V DC
GND
Technical data
24 Vdc
C
0 Vdc
NC
D
COM
+
77