Sequencer Flow Diagram Left - Lenze ESV251 1S Series Operating Instructions Manual

Frequency inverter
Table of Contents

Advertisement

4.5.9.1

Sequencer Flow Diagram Left

Drive Stop/Start Control
Start from
Local Keypad
Start from
Terminal Strip
Start from
Remote Keypad
(1)
Start from Network
(SMV communications
module)
If none of the digital inputs (TB-13A,B,C or D) are asserted
but a start signal is given from the Start/Stop source (P100)
then the drive will run at the output frequency value governed by
(1)
Refer to relevant communications module user guide for starting from a
communications network, RS485 etc..
(2)
Refer to P100 description in the SMV Operating instructions for further
combinations of start sources.
(3)
TB-13D available on SMV models rated 15HP (11kW) or greater.
> Selections shown as default values
WARNING
If the input defined to "Start Sequence" is opened during a sequence, the drive will exit sequencer
mode and will run at the specified standard or alternate speed source (dependent on drive
configuration).
Lenze SMVector 13554876 EDBSV01 EN v21.0
Sequencer Flow Diagram
Digital Input priority:
TB-13A - Lowest
TB-13B
TB-13C
(3)
TB-13D - Highest
(2)
P700
P100
Sequencer
mode
disabled
0
1
0
1
2
2
3
3
WARNING
the frequency reference source (P101).
Notes
Commissioning
"Start Segment" number selection
P121
P122
P123
24
24
3
2
Start
Segment
P701
P124
24
24
Start
Segment
P702
Start
Segment
P703
Start
Segment
P704
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
55