6 Troubleshooting

6.1 Configuring Port Mirroring Settings

Enable/disable the port-mirroring function for network troubleshooting with a network analyzer tool.
1.
In MyDrive Insight, go to Setup and Service → Interface Configuration → Port Mirroring Settings.
Table 26: Port Mirroring Settings
Function
Source port
Destination port
Block RX from destination port
Enable port mirroring

6.2 Identifying a Drive

For easy identification of a drive, the winking function makes the fieldbus indicator LEDs ST, X1, and X2 flash yellow. The function is
enabled in MyDrive
Insight under Device Status by clicking the device name in live mode.
®
Illustration 12: Enabling Winking in MyDrive
See
Table 27
for more information on interpreting the LED signals.

6.3 Fieldbus Indicator LEDs

The fieldbus indicator LEDs are in the top right corner of the control panel.
Danfoss A/S © 2023.09
Selections
Description
Frames are mirrored from this port.
-
X1
-
X2
Frames are mirrored to this port.
-
X1
-
X2
Enable/disable
Device does not receive any frames from Destination Port when en-
abled.
Enable/disable
Enable the Port Mirroring feature.
Insight
®
Troubleshooting
AQ456329149698en-000101 / 136R0334 | 37