Digital output — For connecting external devices such as relays and LEDs. Connected devices can be activated by
the VAPIX® Application Programming Interface or from the device's web interface.
Digital input — For connecting external devices that can toggle between an open and closed circuit, for example
PIR detectors, door/window contacts, and glass break detectors.
Function
0 V DC (-)
DC output
Configurable (Input
or Output)
Function
0 V DC (-)
DC output
Configurable (Input
or Output)
Function
0 V DC (-)
DC output
Pin
Notes
1
2
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
3–4
Digital input – Connect to pin 1 to activate, or leave
floating (unconnected) to deactivate.
Digital output – Internally connected to pin 1 (DC
ground) when active, and floating (unconnected) when
inactive. If used with an inductive load, e.g. a relay, a
diode must be connected in parallel with the load, for
protection against voltage transients.
Pin
Notes
1
2
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
3–6
Digital input – Connect to pin 1 to activate, or leave
floating (unconnected) to deactivate.
Digital output – Internally connected to pin 1 (DC
ground) when active, and floating (unconnected) when
inactive. If used with an inductive load, e.g. a relay, a
diode must be connected in parallel with the load, for
protection against voltage transients.
Pin
Notes
1
2
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
85
Specifications
0 V DC
12 V DC
Max load =50 mA
0 to max 30 V DC
0 to max 30 V DC, open
drain, 100 mA
Specifications
3.3 V DC
Max load = 250 mA
0 to max 40 V DC
0 to max 40 V DC, open
drain, 100 mA
Specifications
0 V DC
12 V DC
Max load =50 mA