Axis Q6075-S User Manual page 77

Hide thumbs Also See for Q6075-S:
Table of Contents

Advertisement

AXIS Q6075-S PTZ Network Camera
Specifications
Function
DC ground
DC output
Digital Input
Digital Output
Function
DC ground
DC output
Configurable
(Input or Output)
Function
DC ground
DC output
Configurable
(Input or Output)
Example
Pin
Notes
1
2
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
3
Connect to pin 1 to activate, or leave floating (unconnected)
to deactivate.
4
Internally connected to pin 1 (DC ground) when active,
and floating (unconnected) when inactive. If used with an
inductive load, e.g., a relay, connect a diode in parallel with
the load, to protect against voltage transients.
Pin
Notes
1
2
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
3–4
Digital input – Connect to pin 1 to activate, or leave floating
(unconnected) to deactivate.
Digital output – Internally connected to pin 1 (DC ground) when
active, and floating (unconnected) when inactive. If used with an
inductive load, e.g., a relay, connect a diode in parallel with the load,
to protect against voltage transients.
Pin
Notes
1
2
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
3–6
Digital input – Connect to pin 1 to activate, or leave floating
(unconnected) to deactivate.
Digital output – Internally connected to pin 1 (DC ground) when
active, and floating (unconnected) when inactive. If used with an
inductive load, e.g., a relay, connect a diode in parallel with the load,
to protect against voltage transients.
77
Specifications
0 V DC
12 V DC
Max load = 25 mA
0 to max 30 V DC
0 to max 30 V DC, open drain,
100 mA
Specifications
0 V DC
12 V DC
Max load = 50 mA
0 to max 30 V DC
0 to max 30 V DC, open drain,
100 mA
Specifications
0 V DC
12 V DC
Max load = 50 mA
0 to max 30 V DC
0 to max 30 V DC, open drain,
100 mA