AXIS Q6075-S PTZ Network Camera
Specifications
NOTICE
TICE
NO
NO
TICE
The product shall be connected using a shielded network cable (STP) or an optical fiber cable. All cables connecting the
product to the network shall be intended for their specific use. Make sure that the network devices are installed in accordance
with the manufacturer's instructions. For information about regulatory requirements, see .
NOTICE
NO
NO
TICE
TICE
To comply with the IP66-rated design of the camera and maintain the IP66 protection, the supplied RJ45 Push-pull Connector
(IP66) shall be used. Alternatively, use the RJ45 IP66-rated cable with premounted connector which is available from your
Axis reseller. Do not remove the plastic network connector shield from the camera.
NOTICE
TICE
NO
NO
TICE
The product shall be connected using a shielded network cable (STP). All cables connecting the product to the network shall
be intended for their specific use. Make sure that the network devices are installed in accordance with the manufacturer's
instructions. For information about regulatory requirements, see the Installation Guide at www.axis.com.
I/O connector
Use the I/O connector with external devices in combination with, for example, motion detection, event triggering, and alarm
notifications. In addition to the 0 V DC reference point and power (12 V DC output), the I/O connector provides the interface to:
Use the I/O connector with external devices in combination with, for example, event triggering and alarm notifications. In addition to
the 0 V DC reference point and power (DC output), the I/O connector provides the interface to:
Digital input - For connecting devices that can toggle between an open and closed circuit, for example PIR sensors, door/window
contacts, and glass break detectors.
Supervised input - Enables possibility to detect tampering on a digital input.
Digital output - For connecting external devices such as relays and LEDs. Connected devices can be activated by the VAPIX®
Application Programming Interface, through an event or from the device's web interface.
A digital light sensor - For receiving a value of the ambient light intensity from an external light sensor. This is used to control the
device's day and night functionality.
Note
The I/O connector is connected to the housing (fan/heater) on delivery. In case of a fan or heater error, an input signal will be
triggered in the camera. Set up an action rule in the camera to configure which action the signal shall trigger.
The I/O connector is connected to the housing (fan/heater) on delivery. In case of a fan or heater error, an input signal will
be triggered in the camera. Set up an action rule in the camera to configure which action the signal shall trigger. For
information about events and action rules, see the user manual available on axis.com.