User Options 1

User Options 1 can be enabled or disabled for a selected
user so that the level of access to the system may be
altered. The following options are available:
# Enable for Partition 1
On: The user can access Partition 1.
Off: The user cannot access Partition 1.
$ Enable for Partition 2
On: The user can access Partition 2.
Off: The user cannot access Partition 2.
%, Enable for Partition 3 (Premier 816/832 Only)
On: The user can access Partition 3.
Off: The user cannot access Partition 3.
&, Enable for Partition 4 (Premier 816/832 Only)
On: The user can access Partition 4.
Off: The user cannot access Partition 4.
', Allow Arming
On: The user can arm the partitions they have been given
access to.
Off: The user cannot arm any partitions.
), Allow Bypassing
On: The user can bypass zones in partitions they have
been given access to.
Off: The user cannot bypass zones.
*, Allow Disarming
On: The user can disarm the partitions they have been
given access to.
Off: The user cannot disarm any partitions.
"
The Engineer code (User 00) can only disarm the
system if the system was armed with the Engineer
code.
!, Allow User Functions
On: The user can access the following user functions:
Reset
View Alarm Log
View Service Faults
Enable Chime
Change Own Code
Off: The user cannot access the above user functions.

User Options 2

User Options 2 can be enabled or disabled for a selected
user so that the level of access to the system may be
altered. The following options are available:
#, Enable One Time Use Access Code
On: The Access code can only be used once to arm and
disarm the system. After the Access code has been
used to disarm the system it is automatically deleted.
Off: The Access code behaves normally.
INS141-6
!#
$, Time Lock Code with Control Timer 1
On: When Control Timer 1 is on, the Access code will not
be accepted by the system. When Control Timer 1 is
off, the Access code will be accepted by the system.
Off: The Access code will be accepted at all times.
%, Enable Open Reporting
On: The system will report an 'Open' condition to the alarm
receiving centre when the Access code is used to
disarm one or more partitions.
Off: The system will not report an 'Open' status.
"
The panel will always send an open signal after an
alarm even if this option is disabled.
&, Enable Close Reporting
On: The system will report a 'Close' condition to the
monitoring station when the Access code is used to
arm one or more partitions.
Off: The system will not report a 'Close' condition.
', Enable User as Duress Code
On: The Access code will report a 'Duress' condition to the
monitoring station when the Access code is used.
Off: The Access code behaves normally.
), Activate Door Strike Output
On: When a user Access code is entered, the output type
"Door Strike" is activated for 2 seconds.
Off: The user Access code will not activate the "Door
Strike" output.
*, Allow Global Bell/Sounder Silence
On: This option allows users to silence the bell and internal
sounder for any partition, even if the user is not
assigned to the partition that is in alarm. The user
cannot disarm or reset the partition if they are not
assigned to it.
Off: The user can only silence alarms for partitions that are
assigned to their code.

User Options 3

User Options 3 can be enabled or disabled for a selected
user so that the level of access to the system may be
altered. The following options are available:
#, Allow Engineer Code Programming
On: The Access code can access User 00 (Engineer) in the
Program New Users menu (menu 80).
!$
Off: The Access code cannot access user 00 in the
Program New Users menu.
$, Allow NVM Locking
On: The Access code is allowed to lock/unlock the NVM
(providing "Allow Engineer Programming" is enabled).
Once the NVM is locked the "Load Defaults" jumper
pins on the main control panel are disabled, thus
preventing the panel from being defaulted.
Off: The Access code cannot lock/unlock the NVM.