Chapter 4 – I/O Configuration
4.5
M
L
ULTI
OAD
Figure 4.6
Note: With only two states returned from the air eliminator, flow must be completely stopped to purge
air. To purge air by only slowing the rate, a 3 output air eliminator head must be used.
Note: When the level drops below Low, the power will be removed from the digital valves, stopping flow
before the air eliminator is completely drained.
MultiLoad II Mobile Installation Guide: Version C
II 2 O
A
E
UTPUT
IR
LIMINATOR
MultiLoad II Digital/ Analog I/O Board Field Wiring: 2 Output Air Eliminator