Specifications
Approval & Codes
This appliance is certifi ed to ANSI Z21.88-2017/CSA
2.33-2017 American National Standard / CSA Standard
for Vented Gas Fireplace Heaters for use in Canada
and USA, and to CGA 2.17-91 High Altitude Standard in
Canada. This appliance is for direct vent installations.
This appliance complies with CSA P.4.1-15 Testing
method for measuring annual fi replace effi ciencies.
The installation must conform to local codes or, in
the absence of local codes, with the National Fuel
Gas Code, ANSI Z223.1/NFPA 54 or the Natural Gas
and Propane Installation Code CAN/CGA-B149.1. Only
qualifi ed licensed or trained personnel should install
this appliance.
This appliance must be electrically grounded in
accordance with local codes, or, in the absence of local
codes, with the National Electrical Code, ANSI/NFPA 70
or the Canadian Electrical Code, CSA C22.1.
Ratings
Model
Gas
Altitude (Ft.)*
Input Maximum (Btu/h)
Input Minimum (Btu/h)
Manifold Pressure (in w.c.)
Minimum Supply Pressure (in w.c.)
Maximum Supply Pressure (in w.c.)
Main Burner Injector Marking
Pilot Injector Marking
Min. Rate By-Pass Screw
*High Altitude Installations
Input ratings are shown in BTU per hour and are
certifi ed without deration for elevations up to 4,500
feet (1,370 m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the current
ANSI Z223.1 and/or local codes having jurisdiction.
Heating value of gas in some areas is reduced to
compensate for elevation—consult your local gas
utility to confi rm.
For installations at elevations above 4,500 feet
(1,370 m) in Canada, please consult provincial and/or
local authorities having jurisdiction.
6
1000JN
1000JP
Natural
Propane
0-4,500 feet*
25,000
24,000
12,000
11,000
3.2"
9.5"
5"
11"
10"
14"
750
260
51
30
175
105
Supply Gas
Heater engines 1000JN is used with natural gas.
Heater engines 1000JP is used with propane gas.
The supply pressure must be between the limits
shown in the Ratings section.
The supply connection is 3/8"
NPT male and located on the
right hand side of the fi rebox.
A shut-off valve (not supplied)
is required on the supply line to
isolate the unit during service.
See Connect Gas Supply section
for details.
Conversion Kits
The 1000J is supplied as natural gas or propane gas
and is fi eld convertible between fuels. See instructions
packaged with the conversion kits for further
information.
Electrical
The 1000J is designed to run on battery power and
does not require an electrical power source to operate
as a heater. However, it requires electrical power
to operate optional 1095CFK Circulating Fan Kit or
GV60PAK Power Adapter.
Outdoor Conversion Kit
The 1000J models are supplied standard for indoor
applications and may be adapted for installation
in specifi c "outdoor" applications protected from
weather as defi ned in the GV60CKO outdoor
conversion kit manual.
 WARNING
Optional electrical accessories ARE NOT
ALLOWED when adapting appliance for
outdoor use.
This appliance is designed and approved as a
supplemental heater and provides the potential
for most energy conservation when used while
attended. The use of an alternate primary heat
source is advisable.