Specifi Cations - Valor H4 Series Installation & Owner's Manual

Direct vent natural/propane gas
Table of Contents

Advertisement

Approvals & codes
These appliances are certifi ed by ANSI Z21.88 /
CSA 2.33 American National Standard / CSA Standard
for Vented Gas Fireplace Heaters for use in Canada
and USA. These appliances are for installation directly
venting through an outside wall or through the roof.
Conversion between fuels may only be done using the
approved conversion kits listed in the section Options.
These appliances comply with CSA P.4.1-15 Testing
method for measuring annual fi replace effi ciencies.
The installation must conform with local codes or, in
the absence of local codes with the National Fuel Gas
Code, ANSI Z223.1/NFPA 54 or the Natural Gas and
Propane Installation Code CAN/CGA-B149.1. Only
qualifi ed licensed or trained personnel should install
these appliances.
These appliances, when installed, must be electrically
grounded in accordance with local codes or, in the
absence of local codes, with the National Electrical
Code, ANSI/NFPA 70 or the Canadian Electrical Code,
CSA C22.1.
Ratings
*Tested to CGA - 2.17-91 High Altitude Standard in
Model
Gas
Altitude (Ft.)*
Input Maximum (Btu/h)
Input Minimum (Btu/h)
Manifold Pressure (in w.c.)
Min. Supply Pressure (in w.c.)
Max. Supply Pressure (in w.c.)
Canada. In the USA, installations may require deration
over 2000 feet—check local codes.
*High Altitude Installations
Input ratings are shown in BTU per hour and are
certifi ed without deration for elevations up to 4,500 feet
(1,370 m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the current
ANSI Z223.1 and/or local codes having jurisdiction.
Heating value of gas in some areas is reduced to
compensate for elevation—consult your local gas utility
to confi rm.
For installations at elevations above 4,500 feet
(1,370 m) in Canada, please consult provincial and/or
local authorities having jurisdiction.
Specifi cations
Supply Gas
Heater engine units 650JN are used with natural gas
installations.
Heater engine units 650JP are used with propane gas
installations.
The supply pressure
must be between the
limits shown in the table
above.
The supply connection is
⅜ inch NPT.
The opening for the gas
supply line is at the left
side of the
appliance.
Venting options
Direct vent installations (solid piping)
A list of all approved venting accessories is shown on
pages 48–49 of this manual.
NOTE: An 817VAK Vent Adapter is required in all
cases.
Direct Vent Co-Linear Installations (fl exible piping)
Converts the appliance outlet collars to accept two
3-inch diameter fl ex liners for installation into existing
JN
JP
solid-fuel burning fi replaces and chimneys. Requires a
Natural
Propane
co-linear adapter at the appliance and either a co-linear
0-4,500 feet*
terminal or co-linear-to-co-axial adapter and terminal
24,000
24,000
at the top of the chimney. A list of approved venting
6,500
13,000
accessories is shown on pages 48–49 of this manual.
3.95
10.0
Outdoor Conversion Kit
5.0
11.0
The 650J model is supplied standard for indoor
11.0
14.0
applications and may be adapted for installation in
specifi c "outdoor" applications protected from weather
as defi ned in the GV60CKO outdoor conversion kit
manual.
X
WARNING
!
O p t i o n a l e l e c t r i c a l a c c e s s o r i e s
A R E N O T A L L O W E D w h e n a d a p t i n g
a p p l i a n c e f o r o u t d o o r u s e .
This appliance is designed and approved as a
supplemental heater and provides the potential
for most energy conservation when used while
attended. The use of an alternate primary heat
source is advisable.
QUALIFIED
INSTALLER
X
19