Specifications
Approval & Codes
This appliance is certifi ed to ANSI Z21.88/CSA 2.33
American National Standard / CSA Standard for
Vented Gas Fireplace Heaters for use in Canada and
USA, and to CGA 2.17-91 High Altitude Standard in
Canada. This appliance is for direct vent installations.
This appliance complies with CSA P.4.1-15 Testing
method for measuring annual fi replace effi ciencies.
The installation must conform to local codes or, in
the absence of local codes, with the National Fuel
Gas Code, ANSI Z223.1/NFPA 54 or the Natural Gas
and Propane Installation Code CAN/CGA-B149.1. Only
qualifi ed licensed or trained personnel should install
this appliance.
This appliance must be electrically grounded in
accordance with local codes, or, in the absence of local
codes, with the National Electrical Code, ANSI/NFPA 70
f i r e - p a r t s . c o m
or the Canadian Electrical Code, CSA C22.1.
Ratings
Model
Gas
Altitude (Ft.)*
Input Maximum (Btu/h)
Input Minimum (Btu/h)
Manifold Pressure (in w.c.)
Minimum Supply Pressure (in w.c.)
Maximum Supply Pressure (in w.c.)
Main Burner Injector Marking
Pilot Injector Marking
Min. Rate By-Pass Screw
*High Altitude Installations
Input ratings are shown in BTU per hour and are
certifi ed without deration for elevations up to 4,500
feet (1,370 m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the current
ANSI Z223.1 and/or local codes having jurisdiction.
Heating value of gas in some areas is reduced to
compensate for elevation—consult your local gas
utility to confi rm.
For installations at elevations above 4,500 feet
(1,370 m) in Canada, please consult provincial and/or
local authorities having jurisdiction.
6
1000KN
1000KP
Natural
Propane
0-4,500 feet*
25,000
24,000
12,000
11,000
3.2"
9.5"
5"
11"
10"
14"
750
260
51
30
175
105
Supply Gas
Heater engines 1000KN is used with natural gas.
Heater engines 1000KP is used with propane gas.
The supply pressure must be between the limits
shown in the Ratings section.
The supply connection is 3/8"
NPT male and located on the
right hand side of the fi rebox.
A shut-off valve (not supplied)
is required on the supply line to
isolate the unit during service.
See Connect Gas Supply section
for details.
Conversion Kits
The 1000K is supplied as natural gas or propane gas
and is fi eld convertible between fuels. See instructions
packaged with the conversion kits for further
information.
Electrical
The 1000K is designed to run on battery power and
does not require an electrical power source to operate
as a heater. However, it requires electrical power
to operate optional 1095CFK Circulating Fan Kit or
GV60PAK Power Adapter.
HeatShift™System
The 1000K are designed to allow the installation of
the optional HeatShift System, a convection system
that redistributes the warm air fl ow away from the
fi replace opening to a more desirable location using
natural convection, without use of a fan.
The warm air fl ow may be relocated to a position
higher up the wall, or even to another room. The
result is much cooler wall temperatures above the
fi replace opening for locating televisions, artwork, etc.
Please note that the framing and mantel clearances
are aff ected by the installation of the HeatShift
System. Refer to "Appendix D—HeatShift™System™"
on page 70 for more information.
Outdoor Conversion Kit
The 1000K models are supplied standard for indoor
applications and may be adapted for installation
in specifi c "outdoor" applications protected from
weather as defi ned in the GV60CKO outdoor
conversion kit manual.