Parameter Settings - Danfoss VLT Refrigeration Drive FC 103 Operating Instructions Manual

Low harmonic drive
Hide thumbs Also See for VLT Refrigeration Drive FC 103:
Table of Contents

Advertisement

Commissioning
The information displayed on the LCP can be customised
for user application. Select options in the Quick Menu
Q3-13 Display Settings.
Callout
Display
1
1.1
2
1.2
3
1.3
4
2
5
3
Table 5.2 Legend to Illustration 5.1, Display Area
5
5
(Frequency Converter Side)
B. Display menu keys
Menu keys are used for menu access for parameter set-up,
toggling through status display modes during normal
operation, and viewing fault log data.
Callout
6
Status
7
Quick Menu Allows access to programming
8
Main Menu Allows access to all programming
9
Alarm Log
Table 5.3 Legend to Illustration 5.1, Display Menu Keys
C. Navigation keys and indicator lights (LEDs)
Navigation keys are used for programming functions and
moving the display cursor. The navigation keys also
provide speed control in local (hand) operation. There are
also 3 frequency converter status indicator lights in this
area.
Callout
Key
10
Back
11
Cancel
12
Info
13
Navigation
keys
14
OK
Table 5.4 Legend to Illustration 5.1, Navigation Keys
56
Parameter number
Default setting
0-20
Reference %
0-21
Motor current
0-22
Power [kW]
0-23
Frequency
0-24
kWh counter
Key
Function
Shows operational information.
parameters for initial set-up instructions
and many detailed application
instructions.
parameters.
Displays a list of current warnings, the
last 10 alarms, and the maintenance log.
Function
Reverts to the previous step or list in the
menu structure.
Cancels the last change or command as
long as the display mode has not
changed.
Press for a definition of the function being
displayed.
Press to move between items in the menu.
Press to access parameter groups or to
enable an option.
Danfoss A/S © 08/2015 All rights reserved.
®
VLT
Refrigeration Drive FC 103 Low Harmonic Drive
Callout
15
16
17
Table 5.5 Legend to Illustration 5.1, Indicator Lights (LEDs)
D. Operation keys and reset
Operation keys are located at the bottom of the LCP.
Callout
18
19
20
21
Table 5.6 Legend to Illustration 5.1, Operation Keys and Reset
NOTICE
The display contrast can be adjusted by pressing [Status]
and [
]/[

5.3.3 Parameter Settings

Establishing the correct programming for applications
often requires setting functions in several related
parameters. Details for parameters are provided in
chapter 9 Appendix A - Parameters.
Programming data is stored internally in the frequency
converter.
Indicator
Light
Function
ON
Green
The ON light activates when the
frequency converter receives
power from mains voltage, a DC
bus terminal, or an external 24 V
supply.
WARN
Yellow
When a warning is issued, the
yellow WARN light comes on
and text appears in the display
area identifying the problem.
ALARM
Red
A fault condition causes the red
alarm light to flash and an alarm
text is displayed.
Key
Function
Hand On
Starts the frequency converter in local
control.
An external stop signal by control
input or serial communication
overrides the local hand on.
Off
Stops the operation but does not remove
power to the frequency converter.
Auto On
Puts the system in remote operational
mode.
Responds to an external start
command by control terminals or
serial communication.
Reset
Resets the frequency converter or active
filter manually after a fault has been
cleared.
] keys.
For back-up, upload data into the LCP memory.
To download data to another frequency
converter, connect the LCP to that unit and
download the stored settings.
MG16N102