Wacker Neuson RD 24 Instruction Manual page 65

Tandem roller / combination roller
Hide thumbs Also See for RD 24:
Table of Contents

Advertisement

0
I
0
I
0
0381-200_1
BA RD24_RD28 en us 06
356
Battery isolating switch
Voltage spikes!
Damage or destruction of electrical components.
I
Only interrupt the circuit at the battery isolating switch when the
engine is at a standstill and when the electrical system is switched
off!
0356-200
The circuit to the minus terminal of the battery is interrupted at the battery
isolation switch. All electric components will be off.
Electrical circuit interrupted — position 0
(key released)
Electrical circuit closed — position I
(key latched)
373
Sprinkling stage
When the sprinkling [317] is switched on, the water consumption can
be selected from several sprinkling stages. Each actuation of the switch
causes a stage increment. An illuminated pilot light [232] indicates the
selected level.
Increasing the stage — PRESS +
Reduce the state — PRESS -
0373-200
380
Additive sprinkling
The sprinkling is activated as long as this switch is pressed.
0341-200
381
Seat heating
On — position I
Off — position 0
Instruments and operating elements
N OT IC E
Operation
004-03
65