SmartACU2000D Smart Array Controller
User Manual (With PID Modules)
Figure 7-14 Removing a faulty PID module
Step 6 Install a new PID module.
Step 7 Open the maintenance compartment door of the PID module, and remove the
cover from the connection box.
Step 8 Connect the removed cables to the new PID module based on the cable labels.
Step 9 Secure the pipe connector to the PID module.
Step 10 Install the connection box cover and close the maintenance compartment door of
the PID module.
Step 11 Install the support bar and close the PID module cabinet door.
----End
Issue 05 (2023-09-26)
NO TE
After ensuring that the PID module is powered on, set parameters by referring to the
SmartLogger3000 User Manual .