Start & Stop Sequence View - Kemppi MasterTig 235ACDC GM Operating Manual

Hide thumbs Also See for MasterTig 235ACDC GM:
Table of Contents

Advertisement

3.3.4 Start & stop sequence view
The parameters diagram view makes base parameter identification and setting easy. From pre-gas time to post-gas
time and everything in between, you can quickly select and adjust the needed parameter value.
To adjust parameters:
1.
Go to the Start & stop sequence view.
2.
Turn the control knob (1) to browse through the parameters.
3.
Select a parameter for adjusting by pressing the control knob button (1).
4.
Adjust the parameter by turning the control knob (1).
5.
Close the parameter setting by pressing the control knob (1).
Adjustable parameters in all welding modes:
Trigger logic: 2T / 4T / 4T LOG / 4T LOG + Minilog (Default = 2T)
Welding mode: Continuous / Spot / MicroTack
Welding current: Default = 50 A.
Ignition mode: Lift TIG / High frequency (HF) ignition
Adjustable parameters in continuous welding:
Pre gas: 0.0 s ... 10.0 s, Auto, 0.1 s step (Default = Auto)
Search arc: OFF / 5 % ... 90 %, step 1 % (Default = OFF)
Upslope: OFF / 0.1 s ... 5.0 s, 0.1 s step (Default = 0.0 s)
Hot start level: -80 % ... 100 %, 1 % step (Default = OFF, 0 %)
Hot start time: 0.1 s ... 5.0 s, 0.1 s step (Default = 1.2 s)
>> This is not available with 4T trigger logic.
Minilog level: -99 % ... 125 %, 1 % step (Default = OFF, 0 %)
© Kemppi
MasterTig 235ACDC, 325DC, 335ACDC
41/77
Operating manual - EN
1920900 / 1939

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mastertig 325dc gMastertig 325dcMastertig 325dc gmMastertig 335acdcMastertig 335acdc gmMastertig 335acdc g ... Show all

Table of Contents