Warning code
1
2
3
4
5
6
7
16
17
18
20
24
28
32
33
34
The warnings can be reset by pressing a push-button (see table):
Machine control
Pushbutton
7.3
Error messages
Depending on the options of the machine display, a fault is shown as follows:
Display type - machine control
Graphic display
two 7-segment displays
one 7-segment display
The possible cause of the fault is signalled by a corresponding fault number (see table). In the case of an
error, the power unit shuts down.
The possible error numbers displayed depend on the machine series and version!
•
If multiple errors occur, these are displayed in succession.
•
Document machine errors and inform service staff as necessary.
Error
Possible cause
3
Tacho error
Wire feeder is not connected
4
Temperature error
099-000141-EW501
22.03.2023
Possible cause
Machine excess temperature
Half-wave failures
Welding torch cooling warning
Gas warning
See warning number 3
Welding consumable (wire electrode)
fault
CAN bus failure
Shielding gas warning
Plasma gas warning
Forming gas warning
Coolant temperature warning
Coolant flow warning
Wire stock warning
Encoder malfunction, drive
Drive is operating under overload con-
ditions
JOB unknown
Smart
Remedy
Allow the machine to cool down
Check process parameters
Check coolant level and refill if necessary
Check gas supply
-
Check wire feeding (with machines with filler
wire)
Inform service.
Check gas supply
Check gas supply
Check gas supply
Check coolant level and refill if necessary
Check coolant supply; check coolant level
and, if necessary, fill up
Check wire feeding (with machines with filler
wire)
Inform service.
Adjust mechanical load
Select alternatives JOB
Classic
Comfort
Display
Remedy
Check wire guide / hose package.
Switch off cold wire mode in the machine configuration
menu (off status). Connect the wire feeder.
Allow the machine to cool.
Rectifying faults
Error messages
Smart 2
Synergic
Comfort 2
79