Calibrating the optics

Calibration is the process to determine your Emblaser 2's optimal focus setting. An accurately
calibrated optical system can assist with achieving finer detain and cutting through tougher
materials.
Calibration Card
Calibration Card
1.
Place one of the supplied calibration cards in the centre
of your workspace, on top of your cutting mats. Use the
Darkly Labs
arrows on the card to help centre it.
If you do not have a calibration card, a sheet of white
copy paper will also work.
2.
Load the calibration file 'E2_calibration.gcode' into
Laserweb. This file can be found on the Emblaser 2
internal storage drive or downloaded from here:
Close the lid, enable the laser and run the job.
3.
Select the number that corresponds to the thinnest
line. This is called the 'Tool Offset' value. You can
examine the vertical and horizontal lines to help you
choose.
Darkly Labs
4.
In Laserweb, navigate to 'Settings/Machine'.
Set the 'Tool Offset' value as determined in the previous
step.
Place calibration card on
workspace
Run the Calibration Job
http://tinyurl.com/e2start
Select value
Enter Value into Laserweb
19