CHECKING THE FLUE AND FIRE OPENING
Check that the chimney conforms to the required specifications as previously stated. Examine the condition and
carry out any remedial work including removing any debris from the base.
If the flue has been used for solid fuel it should be swept prior to the installation
Prior to installing the appliance a smoke test (using a smoke bomb) should be carried out to check that
satisfactory smoke clearance has been established.
If all the smoke is not drawn into the flue, pre-heat the flue with a blowtorch or similar and re-check. If there is any
uncertainty examine for the cause and, if necessary, seek expert advice.
No combustible material should be fitted inside the fireplace opening.
When installing this appliance against a dry lined (plasterboard) wall ensure that any void between the
plasterboard and the wall is sealed with a suitable non-combustible material (i.e. plaster or mortar).

SECTION NINE To Install the Appliance (installation instructions)

GAS SUPPLY ROUTING
Use rigid or semi – rigid tube to connect the supply. Determine the gas
supply pipe route to the appliance before installing the fire.
Fixing Firebox Assembly
Slide the firebox into the fireplace open guiding the gas supply pipe
through the hole at the rear LH bottom of the firebox.
Retain the Firebox using wall plugs and screw using the four holes
within the firebox flange.
Refit the grommet over the pipe and seal around the inlet hole.
The Fireplace frame can now be located onto the firebox assembly and
retained using the six off M4 nuts provided.
Remove the gas connection cover located within the burner shelf left
hand side and connect to the restrictor elbow provided.
Note: - The isolation valve must be fitted at a angle to allow access to the
restrictor plug plus gas pressure test nipple.
At this point the fireplace or false chimney breast front will need to be
constructed.
Connect battery pack as described in section 2. (Operating the
appliance). Locate the battery pack in the holder positioned within the
fireplace frame.
Now check that a signal is being received by pointing the remote control
hand set in the direction of the appliance and press ON / OFF Key for at
least 2 seconds. On release a bleep should be heard and the ignition
process will start.