Section Five Appliance Data; Installation Instructions - Infinity 890 BF Owner's Manual

Room sealed inset live fuel effect gas fire
Table of Contents

Advertisement

INFINITY 890 BF
SECTION FIVE
Fire Box dimensions:
Forward Projection:
Overall Trim dimensions........................................Height
Trim Forward dimensions........................................................23mm
Weight:
Flue Length................................................100mm (minimum) to 1000mm (maximum)
Pressure Test Point Location:
Gas Connection:
Data Badge Location:
MODEL
Category of appliance
NO
Efficiency Class
Gas Category
Gas Type
Gas Pressure +/- 1.0mbar
Gas Input
Injectors size
NOTE: The efficiency of this appliance has been measured as specified in BS EN613-2001 and the
result is 82.1% natural gas. The gross calorific value of the fuel has been used for this efficiency
calculation. Gastec have certified the test data from which it has been calculated. The efficiency
value may be used in the UK Government's Standard Assessment Procedure (SAP) for energy rating
of dwellings.

Installation Instructions

Appliance Data
Class
X
(Max)
(Min)
Height
Width
Width
1054mm
Standard length supplied with fire 535mm(267.5mm
after cutting). Additional 535mm or 1000mm tubes
supplied as optional extras.(No bends or joined flue
pipes should be used in the flue system).
Gas inlet elbow
8.0mm O/D, tube.
On bottom right hand side of fire box under batteries.
Natural Gas (G20) Version
C
I
G20 Natural Gas
20 mbar
3.4 KW Gross
1.6 kW Gross
220A Mark
13
456mm
970mm
10mm
462mm
35kg
II
5
1
2H
LT 6541 (Iss 4 07/14)