SECTION SIX Appliance Data (installation instructions)

Gas Type:
Gas Pressure:
Pressure Test Point Location:
Gas Input:
Injectors:
Oxy pilot:
NOx Classification ................... 5
Gas Connection:
Data Badge Location:
Battery Remote handset size 3 x 1.5v AAA,
Appliance 6 x 1.5V C high power alkaline.
Appliance Dimension
NOTE: The efficiency of this appliance has been measured as specified in BS7977-1 2009+A1:2013 and the result is
74.40 %. The gross calorific value of the fuel has been used for this efficiency calculation. Gastec have certified the
test data from which it has been calculated. The efficiency value may be used in the UK Government's Standard
Assessment Procedure (SAP) for energy rating of dwellings. Please note: Within the appliance packaging will be a
outlet restrictor, this is there to achieve the maximum efficiency. This, however, may not be fitted due to the flue
underperforming.
When unpacking the appliance please check, the following items are included:
Fuel Bed:
Owner's Manual
NATURAL GAS
CATEGORY I 2 H
20 mbar +/- 1.0mbar
Gas inlet elbow
5.5 kW Gross (Max.)
2.4 kW Gross (Min.)
Mk 360
9079 N.G.
8mm compression: semi-rigid or rigid
Located on the right hand side of the appliance on the base
Air Tray Fireplace Frame Assembly.
Vermiculite
PROPANE GAS
CATERGORY 1 3 P
37 mbar +/- 1.0mbar
5.0kW Gross (Max.)
2.4kW Gross (Max.)
Mk 116
9264 L.P.G.
16
LT6125 (ISS 13)