Please read these instructions carefully before you start installing or using this appliance Keep this booklet handy for future reference This appliance is for use in Great Britain or IRELAND only INFINITY Charlton & Jenrick LTD Telford Shropshire TF3 3AR...
480 FL Instructions CONTENTS PAGE USERS INSTRUCTIONS SECTION ONE Introduction Consumer Protection Information Heath & Safety Notice Introduction Important Information SECTION TWO Operating Appliance Lighting the Appliance Replacing Hand Set Battery Replacing Appliance Battery SECTION THREE Cleaning Cleaning Pilot Assembly...
Page 3
‘hazardous waste and should be disposed of at a site licensed for the disposal of industrial waste. INTRODUCTION The 480 FL as been designed and tested to the requirements of EN 613 and is suitable for use in GB (Great Britain) and IE (Ireland). ...
SECTION ONE Introduction Continued The 480 FL is battery operated; therefore no mains electrical supply is required. Power to the appliance is provided by 6 high power alkaline 1.5V batteries (C size) (a spare set of 6 C batteries is supplied with the appliance).
480 FL Users Instructions SECTION ONE Introduction Continued Care must be taken to prevent any damage being caused to surrounding soft furnishing or decoration; e.g. many embossed vinyl wall coverings may become discoloured if placed too close to the appliance. Combustible material i.e. wall panelling or wallpaper must be removed from behind the fire and fire trim.
Page 6
480 FL Users Instructions SECTION TWO Operating the Appliance Continued below the SET room temperature, the system will move from standby to the high flame level. From this point it will proceed again the modulation process. Note: Due to the temperature checks at timed intervals, the display temperature on the handset may exceed...
Page 7
480 FL Users Instructions SECTION TWO Operating the Appliance Continued Child Lock (Handset) To activate `Child Lock` : Press and hold the Mode Key button for 5 seconds, this will lock and disable the handset and a “padlock” symbol will appear on the bottom of the screen. This can be done while the fire is “off”...
480 FL Users Instructions SECTION THREE Cleaning Warning: - Before you clean any part of the appliance ensure that the appliance is turned off and cold. CLEANING: PILOT ASSEMBLY (Before cleaning ensure that the appliance is turned off and cold) In some instances you may experience ignition problems even when the appliance is new.
480 FL Users Instructions SECTIONTHREE Cleaning Continued REMOVING GLASS PANEL Remove the two side covers LH and RH which are held on with magnets. Undo the two M4 nuts retaining the glass fixing bracket using the tool provided then pull clear from location studs.
Page 10
480 FL Users Instructions SECTION FOUR Fuel Bed Cleaning and Layout Please make sure no loose shapes are placed directly on pilot shield. Place the 2 log shapes along the front edge of the burner top plate. Place a single layer of small bark chippings along the rear of the burner plate.( Please note vermiculite will be provided on LPG...
Page 11
480 FL Users Instructions SECTION FOUR Fuel Bed Cleaning and Layout Place the 2 log shapes along the rear of the air tray assembly. Position a single layer of bark chippings along the front edge of the air tray.
Page 12
480 FL Users Instructions SECTION FOUR Fuel Bed Cleaning and Layout Continued Place the two log shapes as shown. Place the two log shapes as shown. LT 6117 (12/13 Iss 11)
It is advised that a competent person service the 480 FL fire annually. The fire is more likely to provide trouble-free operation.
Page 14
480 FL Installation Instructions SECTION SIX Appliance Data NATURAL GAS PROPANE GAS Gas Type: CATEGORY I 2 H CATERGORY 1 3 P Gas Pressure: 20 mbar +/- 1.0mbar 37 mbar +/- 1.0mbar Pressure Test Point Location: Gas inlet elbow Gas Input: 5.5 kW Gross (Max.)
480 FL Installation Instructions SECTION SEVEN Regulations and Warnings This appliance must only be installed in Great Britain or Ireland. The appliance is suitable for use on natural gas only. GB (Great Britain) This fire does not normally require purpose build ventilation.
Page 16
480 FL Installation Instructions SECTION EIGHT Siting the Appliance CLASS ONE That is a conventional brick or stone chimney as used for a solid fuel appliance with an effective cross- sectional dimension of 225 x 225 mm (9” x 9”) or a lined flue with a minimum diameter of 125mm (5”). The chimney must have a minimum effective height of at least 3 metres.
Page 17
480 FL Installation Instructions SECTION EIGHT Siting the Appliance PREPARING THE OPENING FOR INSTALLATION WITH MARBLE SLIPS 625 - 665mm This area behind the trim/fascia must be clear of combustible 635- 640mm material and be flat for the seal. Floor...
480 FL Installation Instructions SECTION EIGHT Siting the Appliance Continued CHECKING THE FLUE AND FIRE OPENING Check that the chimney conforms to the required specifications as previously stated. Examine the condition and carry out any remedial work including removing any debris from the base.
Page 19
480 FL Installation Instructions SECTION NINE To Install the Appliance Continued CHECKING GAS SOUNDNESS AND RUNNING PRESSURE. Turn on the gas supply to the appliance and check for soundness in accordance with current codes of practice. Turn off the gas supply at the external Isolation valve.
480 FL Installation Instructions SECTION TEN Checking Operation of Fire REFIT GLASS PANEL AND FIREPLACE FRAME COVERS Locate the glass panel within the bottom glass retaining slot and push back against the firebox seals. Locate the glass fixing bracket over the top edge of the glass panel and slide over the two M4 studs.
Page 21
480 FL Maintenance Instructions SECTION ELEVEN Maintenance GENERAL Servicing should be carried out annually by a competent person such as a Gas safe-registered person in accordance with the relevant regulations, to ensure the safe and correct operation of the appliance.
480 FL Maintenance Instructions SECTION ELEVEN Maintenance Continued REPLACEMENT OF OXY-PILOT ASSEMBLY NOTE: If the pilot assembly is replaced it must be replaced by an identical unit from the same manufacturer and replaced as a complete unit. Follow the burner tray removal sequence.
Page 24
Charlton and Jenrick Ltd. 8. The registration form must be returned within 3 months of purchase. INFINITY HELPDESK NUMBER 0845 5195991 Important For future reference we suggest you record the following details here, and keep the receipt as proof of purchase.
Page 26
Date of Fourth annual service: Engineer Name Gas Safe Registration No. We may introduce modifications to products from time to time, and consequently the details given in this booklet are subject to alteration without notice. Infinity Charlton & Jenrick LTD Telford Shropshire TF3 3AR...
Page 28
Post Code TELEPHONE No. PRODUCT DETAILS Model : 480 FL Serial No. Date of Purchase This information can be found on the label attached to the packaging and on the data badge, which is located on the appliance flange, top right behind trim.
Page 32
Infinity 480 FL Infinity 480 FL A-0342 A-0324 (Lpg) (Ng) Product Serial No Product Serial No ID Label Prefix ID Label Prefix Burner Tray / Box Assembly Burner Tray / Box Assembly Top Liner Fitted Top Liner Fitted Complete Log Fuel Bed (6000)