Section Five Appliance Data - Infinity 880 BF Owner's Manual

Room sealed inset live fuel effect gas fire
Table of Contents

Advertisement

INFINITY 880 BF Installation Instructions

SECTION FIVE Appliance Data

Fire Box dimensions:
Forward Projection:
Weight:
Flue Length................................................100mm (minimum) to 600mm (maximum)
Pressure Test Point Location:
Gas Connection:
Data Badge Location:
MODEL
Category of appliance
NO
Efficiency Class
Gas Category
Gas Type
Gas Pressure +/- 1.0mbar
Gas Input
Injectors size
NOTE: The efficiency of this appliance has been measured as specified in BS EN613-2001 and the
result is 80.9% natural gas. The gross calorific value of the fuel has been used for this efficiency
calculation. Gastec have certified the test data from which it has been calculated. The efficiency
value may be used in the UK Government's Standard Assessment Procedure (SAP) for energy rating
of dwellings.
Class
X
(Max)
(Min)
Height
Width
No bends or joined flue pipes should be used in the
flue system.
Gas inlet elbow
8.0mm O/D, tube.
On bottom right hand said of fire box behind trim.
Natural Gas (G20) Version
C
I
G20 Natural Gas
20 mbar
5.0 KW Gross
2.4 kW Gross
360 Mark
12
1030mm
785mm
42mm
35kg
II
3
1
2H
LT 6456 (Iss 2 046/14)