4.2.2 Starting procedure for the TFG
DANGER!
Risk of escaping liquid gas if the truck does not start
Note the safety regulations governing the handling of liquid gas
((see "Safety regulations for handling diesel fuel and LPG" on page 45))
Close the gas bottle shut-off valve.
Set the key switch to "O"
Notify your superior.
Procedure
• Slowly open the shutoff valve on the LPG
bottle.
• Put the key in the key switch. Set key
switch to "I".
• All the indicators light up briefly to test
operation.
Z
All the indicators except for the engine oil
pressure display (82), parking brake
indicator (86), indicator lamp for neutral
(90) and charge current indicator (88)
should go out after a short while. If not,
stop the start-up process and rectify the
fault.
• Now set the ignition / starter key to the "II"
position.
Z
Only apply the starter for a maximum of
15 seconds without interruption. The
truck
contains
mechanism which prevents it from
starting again while the engine is running.
• Release the key as soon as the engine
starts. It automatically reverts to the "I"
position.
Z
All indicators lights except for neutral
setting (90) and parking brake (86)
should go out as soon as the engine
starts. If not, stop the engine immediately
and rectify the fault.
The truck is now ready for operation.
a
restart
blocking
0
76
88
82
86
90
I
II
73