7.2.3 Starting aid
WARNING!
Danger from overheating
Only use an ISO 6722 battery jump lead
with fully insulated terminal pliers and a
lead diameter of at least 25 mm
Z
The jump start connection (152) is located
in the main fuse box on the starter battery.
Procedure
• First connect the positive terminal of the
feeder battery to the jump start connection
(marked with the label in the engine
compartment main fuse box) with the red
lead.
• Connect the negative terminal of the feeder battery and the earth point of the crane
eye on the engine with the black lead.
• To start the industrial truck switch on the ignition with the engine cover open.
• Press the panel switch override button once, (see "Starting the engine with the
cover open" on page 160).
• Start the engine as normal.
• When the engine has started first remove the negative lead followed by the positive
lead
Z
If the starter motor does not switch on the engine after connecting the battery
terminals, check that the battery terminal clips are positioned correctly.