General Specifications
Item
Power supply voltage
Allowable power supply voltage range
Power consumption
Ambient operating temperature
Storage temperature
Ambient operating humidity
Operating environment
Resistance to electrostatic discharge
Electromagnetic field strength
Fast transient/burst noise
Damped oscillatory wave
Vibration resistance
Shock resistance
Dimensions (mm)
Weight
Enclosure ratings
g
Applicable standards
Appendix A
Specifications
24 VDC
20.4 VDC to 26.4 VDC (24 VDC --15% +10%)
15 W max.
0 to +50_C (with no freezing)
--20 to +70_C (with no freezing)
35% to 85% (with no condensation)
No corrosive gases.
Level 3 (IEC801-2)
In air 8 kV, contact 6 kV, indirect 7 kV
10 V/m (IEC801-3)
Power supply line: 2 kV (IEC801-4)
I/O line: 0.25 kV
Power supply line: 1 kV (IEC255-4)
10 to 57 Hz with 0.075 mm single amplitude for a total of 30 min. in X, Y, and
Z directions
2
57 to 150 Hz with 9.8 m/s
Malfunction: 15 G, 3 times each in X, Y, and Z directions
195 x 142 x 56 mm (WxHxD)
(when B7A Interface Unit installed: 195 x 142 x 75 mm (WxHxD))
1.0 kg max.
Front panel: Equivalent to IP65 (front face waterproof construction).
Rear case:
IP20
Terminals:
IP00
EN61131-2 (1995)
EN50081-2 (1992)
Specification
acceleration in X, Y, and Z directions