Touch Switches
Touch Switch Attributes
Touch Switch area
Display frame
Display frame
Touch Switch area
156
The following attributes can be set for the touch switches.
S Display Frame
A display frame of the touch switch can be specified by the following two meth-
ods.
- Fixed-shape Display Frame
This is a frame displaying an area of display frame type that acts as Touch
Switch. There are four kinds of display frames as shown in the table below:
Standard, Solid 1, Solid 2, No Display Frame.
When No Display Frame is selected, only the label is displayed (or nothing if
no label is specified) unless an ON (or flash) instruction is sent from the PC,
or the touch switch is pressed.
Display Frame Type
Standard
Solid 1
Solid 2
No display frame
- Free-shape Display Frame
This is a display frame capable of freely setting the display position and
shape irrespective of Touch Switch area. A shape to be specified can be se-
lected out of Square, Circle, Polygon, and Fan.
For example, free-shape display frame can be used in the following manner.
Example: Setting a display frame inside the touch switch area
Example: Setting a display frame outside the touch switch area
S Reverse Video Entry
This attribute can specify the Touch Switch so as to be shown in reverse video
when it is touched and operated.
S Guide Display
Labels can be assigned to touch switches. When the touch switch is ON, the
label is displayed in reverse video in the case of an NT30 and in the exclusive
Switch OFF
Switch ON
When this position
is pressed
When this position
is pressed
Section
4-7
Shown in reverse video
Shown in reverse video