Selecting The Host Link Baud Rate - Omron NT30C-ST141-E Operation Manual

Programmable terminal
Table of Contents

Advertisement

Setting Communications with the PC Using Memory Switches

3-5-2 Selecting the Host Link Baud Rate

86
When the Host Link is used, the baud rate of the communications with the PC can
be set. Use the Baud Rate switch and select 9600 bps or 19200 bps.
If the NT link has been selected, the Host Link baud rate setting does not have
any effect.
The factory setting has been made at 19200 bps.
Select the baud rate of the communications with the PC by the menu operation
from the System Menu shown below.
[ SYSTEM MENU ]
Quit
Transmit Mode
Maintenance Mode
[ MAINTENANCE MENU ]
Quit
Display History
I/O Check
PT Settings
Init. Memory
< MEMORY SWITCH >
ON
Key Press Sound
Buzzer Sound
ON
Screen Saver
10min
None
Resume Memory Table
Printer
ESC/P MONO.
< MEMORY SWITCH >
Comm. Port
RS232C
Comm. Method
Host Link
Baud Rate
9600
Automatic Reset
None
To set and quit the menu, press the Quit touch switch. The settings made last will
be set and the display will return to the Maintenance Menu.
Select "Maintenance Mode."
Select "Memory Switch."
Memory Switch
Select "Next."
Next
Quit
Each time the Baud Rate
Prev.
Quit
touch switch is pressed, the
setting option 9600 bps alter-
nates with 19200 bps.