Operation Flow By The System Menu; Starting The Nt30/30C - Omron NT30C-ST141-E Operation Manual

Programmable terminal
Table of Contents

Advertisement

Starting the NT30/30C

3-1

Operation Flow by the System Menu

System Program Installation When using the NT30/30C for the first time, erase the system program loaded on
Create the Screen Data
Start Up the NT30/30C (Display the System Menu.) (page 74)
Initialize Memory (page 78)
Memory Switch Setting (page 83)
Transfer the Screen Data (page 89)
Start the Operation (page 91)
System Maintenance (page 100)
3-2

Starting the NT30/30C

74
Follow the procedure below when using the NT30/30C for the first time or when
changing the system.
shipping, and transfer the new system program to the NT30/30C by using the NT
series system installer.
Create the screen data to be displayed on the NT30/30C by using the NT-series
Support Tool.
For the screen data creation, refer to the NT-series Support Tool for Windows
Operation Manual (V061).
Turn ON the power to the NT30/30C.
When no screen data has been registered, the System Menu will be displayed. If
the NT30/30C enters the RUN mode, press appropriate touch switches to dis-
play the System Menu.
Select a System Menu and initialize the NT30/30C Unit memory.
Select the System Menu and set the conditions for communications with the PC
using the memory switch.
Connect the NT-series Support Tool to the NT30/30C and transfer the screen
data from the NT-series Support Tool to the NT30/30C.
For the connection of the NT-series Support Tool, refer to 2-3 Connecting to the
Support Tool (page 21).
Connect to the PC and start the operation.
If an error has occurred during operation, check the I/Os, settings, etc. referring
to this guide.
When the NT30/30C is started, it will enter the RUN mode if system settings and
screen data registration have been completed. If no screen data has been regis-
tered or the screen data are destroyed, the System Menu will be displayed.
Before turning ON the power, check the following DIP switch settings on the
NT30/30C.
• SW2 pin 3 (Switch to the System Menu enabled/disabled) is set to OFF (en-
abled).
• SW2 pin 4 (Screen data forced initialize Yes/No) is set to No (ineffective).
• SW2 pin 7 (System installation effective/ineffective) is set to OFF (starts in nor-
mal RUN mode).
For the DIP switch settings of the Unit, refer to the DIP Switch Settings (page 18).