ACME SPARTAN HYBRID User Manual page 53

Hide thumbs Also See for SPARTAN HYBRID:
Table of Contents

Advertisement

Frost Error
Prism 1/2 Error
Check whether the position of the frost where the magnet is installed
falls off or is damaged.
Check whether there are obstacles in the frost operating range.
Check whether the Hall element on the frost is damaged.
Check whether the lead connecting the Hall element on the frost and
the PCB board is in poor contact or disconnected.
Check whether the motor on the frost is damaged.
Check whether the related circuit of the motor drive board on the
frost is damage.
Check whether the position of the prism where the magnet is
installed falls off or is damaged.
Check whether there are obstacles in the prism operating range.
Check whether the Hall element on the prism is damaged.
Check whether the lead connecting the Hall element on the prism and
the PCB board is in poor contact or disconnected.
Check whether the motor on the prism is damaged.
Check whether the related circuit of the motor drive board on the
prism is damage.