Operation mode
Watchdog timer active (R32.2 [} 36])
Here you can deactivate the watchdog (default: active). If the DC motor output stage fails to receive process
data from the controller for 100 ms when the watchdog is active, the watchdog is triggered, and the motor
stops.
Signed amount representation (R32.3 [} 36])
Here you can activate the signed amount representation (default: inactive).
User switch-on value active (R32.8 [} 36])
You can activate the user switch-on value [} 24]here (the default is inactive).
Velocity control active (R32.15 [} 36])
Here you can deactivate the velocity control (default: active).
I-controller active (R32.14 [} 36])
Here you can deactivate the I-controller (default: active).
KL2542/KS2542
Version: 2.1.0
23