Beckhoff KS2542 Manual page 24

Two channel output stage terminals for dc motors
Table of Contents

Advertisement

KS2000 Configuration Software
Inner window for I-controller active (R32.13 [} 36])
Here you can deactivate the inner window for the I-controller (default: active).
Torque monitoring active (R32.9 [} 36])
Here you can activate torque monitoring (default: inactive).
Overvoltage protection active (R32.10 [} 36])
Here you can activate overvoltage protection (chopper resistor) for channel 2 (default: inactive).
User scaling active (R32.0 [} 36])
Here you can activate user scaling (default: inactive).
Manufacturer scaling active (R32.1 [} 36])
Here you can activate manufacturer scaling (default: inactive).
Register values
User switch-on value (R35 [} 37])
Here you can specify the user switch-on value for the velocity (default: 0).
Switching threshold for MixedDecay (R41 [} 37])
Here you can specify the automatic switch-off threshold for MixedDecay (default: 20%).
Rated motor current (R37 [} 37])
Here you can specify the rated motor current.
The default is 3500 mA
Maximum motor current (R36 [} 37])
Here you can specify the maximum motor coil current.
The default is 5000 mA
Internal motor resistance (R40 [} 37])
Here you can specify the internal motor resistance (default: 1 ohm).
Kp factor (R42 [} 37])
Here you can specify the Kp factor for the internal velocity control (default: 1).
Inner window for I-controller (R43 [} 37])
Here you can specify the Kp factor for the internal velocity control (default: 1%).
The I-component of the velocity control is attenuated towards the zero point. This register specifies the value
from which the attenuation is activated.
Maximum value for I-controller (R44 [} 38])
Here you can specify the maximum value for the I-component (default: 5%).