Starting frequency (Pr. 13)

Pr. 13 "starting frequency"
You can set the starting frequency between 0 and 60Hz.
Set the starting frequency at which the start signal is switched on.
z
Parameter
Factory Setting
Number
13
0.5Hz
<Setting>
Output frequency
(Hz)
60
Pr.13
0
Frequency setting signal (V)
Forward
ON
rotation
Note: The inverter will not start if the frequency setting signal is less than the value set in Pr. 13 "starting
frequency".
For example, when 5Hz is set in Pr. 13, the motor will start running when the frequency setting signal
reaches 5Hz.
z

Load pattern selection (Pr. 14)

Pr. 14 "load pattern selection"
You can select the optimum output characteristic (V/F characteristic) for the application and load
characteristics.
Parameter
Factory Setting
Number
14
0
Pr.14=0
For constant-torque loads
(e.g. conveyor, cart)
100%
100%
Base frequency
Output frequency (Hz)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Setting Range
0.01 to 60Hz
Time
Setting Range
0 to 5
Pr.14=1
Pr.14=2
For lift
For variable-torque loads
Boost for forward rotation...Pr. 0 setting
(Fan, pump)
Boost for reverse rotation...0%
100%
Forward
rotation
Pr.0
Base frequency
Output frequency (Hz)
Output frequency (Hz)
70
PARAMETERS
Related parameters
Pr. 0 "torque boost"
Pr. 80 "motor capacity"
Pr. 81 "number of motor poles"
Pr. 180 to Pr. 186
(input terminal function selection)
Pr.14=3
For lift
Boost for forward rotation...0%
Boost for reverse rotation...Pr. 0 setting
100%
Reverse
rotation
Reverse
Forward
rotation
rotation
Pr.0
Base frequency
Base frequency
Output frequency (Hz)

Advertisement