Mitsubishi Electric FR-A520-2.2K Instruction Manual page 71

Transistorized inverter, high function & low acoustic noise
Hide thumbs Also See for FR-A520-2.2K:
Table of Contents

Advertisement

Func-
Parameter
tion
Number
52
DU/PU main display data selection
53
PU level display data selection
54
FM terminal function selection
55
Frequency monitoring reference
56
Current monitoring reference
57
Restart coasting time
58
Restart cushion time
59
Remote setting function selection
60
Intelligent mode selection
61
Reference I for intelligent mode
62
Ref. I for intelligent mode accel.
63
Ref. I for intelligent mode decel.
64
Starting frequency for elevator mode
65
Retry selection
Stall prevention operation level reduction
66
starting frequency
67
Number of retries at alarm occurrence
68
Retry waiting time
69
Retry count display erasure
70
Special regenerative brake duty
71
Applied motor
72
PWM frequency selection
73
0-5V/0-10V selection
74
Filter time constant
Reset selection/disconnected PU
75
detection/PU stop selection
76
Alarm code output selection
77
Parameter write disable selection
78
Reverse rotation prevention selection
79
Operation mode selection
80
Motor capacity
81
Number of motor poles
82
Motor exciting current (Note 4)
83
Rated motor voltage
84
Rated motor frequency
89
Speed control gain
90
Motor constant (R1) (Note 4)
91
Motor constant (R2) (Note 4)
92
Motor constant (L1) (Note 4)
93
Motor constant (L2) (Note 4)
94
Motor constant (X)
95
Online auto tuning selection
96
Auto tuning setting/status
100
V/F1 (first frequency) (Note 1)
101
V/F1 (first frequency voltage) (Note 1)
102
V/F2 (second frequency) (Note 1)
103
V/F2 (second frequency voltage) (Note 1)
104
V/F3 (third frequency) (Note 1)
105
V/F3 (third frequency voltage) (Note 1)
106
V/F4 (fourth frequency) (Note 1)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Name
Setting Range
0 to 20, 22, 23, 24, 25,
100
0 to 3, 5 to 14, 17, 18
1 to 3, 5 to 14,
17, 18, 21
0 to 400Hz
0 to 500A
0, 0.1 to 5 s, 9999
0 to 60 s
0, 1, 2
0 to 8
0 to 500A, 9999
0 to 200%, 9999
0 to 200%, 9999
0 to 10Hz, 9999
0 to 5
0 to 400Hz
0 to 10,101 to 110
0 to 10 s
0
0 to 15%/0 to 30%/0%
(Note 10)
0 to 8, 13 to 18, 20, 23,
24
0 to 15
0 to 5, 10 to 15
0 to 8
0 to 3, 14 to 17
0, 1, 2, 3
0, 1, 2
0, 1,
0 to 8
0.4 to 55kW, 9999
2, 4, 6, 12, 14, 16, 9999
0 to , 9999
0 to 1000V
50 to 120Hz
0 to 200.0%
0 to, 9999
0 to, 9999
0 to, 9999
0 to, 9999
0 to, 9999
0, 1
0, 1, 101
0 to 400Hz, 9999
0 to 1000V
0 to 400Hz, 9999
0 to 1000V
0 to 400Hz, 9999
0 to 1000V
0 to 400Hz, 9999
58
PARAMETERS
Minimum
Refer
Factory Setting
Setting
〈EC Version〉
Increments
Page:
1
0
1
1
1
1
60Hz 〈50Hz〉
0.01Hz
0.01A
Rated output current
0.1 s
9999
0.1 s
1.0 s
1
0
1
0
0.01A
9999
0.1%
9999
0.1%
9999
0.01Hz
9999
1
0
60Hz 〈50Hz〉
0.01Hz
1
0
0.1 s
1 s

0
0.1%
0%
1
0
1
2
1
1
1
1
1
14
1
0
1
0
1
0
100
1
0
101
0.01kW
9999
104
1
9999
104
1
9999
105
0.1V
200/400V (Note 2)
105
60Hz 〈50Hz〉
0.01Hz
105
0.1%
100%
111
9999
105
9999
105
9999
105
9999
105
9999
105
1
0
111
1
0
112
0.01Hz
9999
113
0.1V
0
113
0.01Hz
9999
113
0.1V
0
113
0.01Hz
9999
113
0.1V
0
113
0.01Hz
9999
113
To
82
82
82
84
84
85
85
87
88
90
90
90
90
91
92
91
91
91
92
93
94
95
96
96
98
99

Advertisement

Table of Contents
loading

Table of Contents