Option List; Stand-Alone Options - Mitsubishi Electric FR-A520-2.2K Instruction Manual

Transistorized inverter, high function & low acoustic noise
Hide thumbs Also See for FR-A520-2.2K:
Table of Contents

Advertisement

7.1 Option List

7 OPTIONS
7.1 Option List

7.1.1 Stand-alone options

Name
Type
Parameter unit
FR-PU04
(8 languages)
……
Parameter unit
FR-CB2
connection cable
……
Cooling fin protrusion
FR-A5CN
attachment
totally enclosed
……
structure specification
FR-A5CV
attachment
……
Attachment for conduit
FR-A5FN
connection
FR-A200E series
……
installation interchange
FR-A5AT
attachment
EMC Directive
……
compatible noise filer
SF
(Note 3)
High-duty brake
FR-ABR-(H)
resistor
(Note 1)
……
Surge voltage
FR-ASF-H
suppressing filter
Power factor improving
FR-BEL-(H)
DC reactor
(Note 1)
Power factor improving
FR-BAL-(H)
AC reactor
(Note 1)
FR-BIF-(H)
Radio noise filter
(Note 1)
FR-BSF01
Line noise filter
FR-BLF
BU-1500 to 15K,
BU brake unit
H7.5K to H30K
FR-BU-15K to 55K,
Brake unit
H15K to H55K
FR-BR-15K to 55K,
Resistor unit
H15K to H55K
FR-RC-15K to 55K,
Power return converter
H15K to H55K
High power factor
FR-HC7.5K to 55K,
converter
H7.5K to H55K
Manual controller
FR-AX (Note 4)
DC tach. follower
FR-AL (Note 4)
Three speed selector
FR-AT (Note 4)
Motorized speed setter
FR-FK (Note 4)
Ratio setter
FR-FH (Note 4)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Application, Specifications, etc.
Interactive parameter unit using LCD display (For use in Japanese,
English, German, French, Spanish, Italian, Swedish and Finnish)
Cable for connection of the operation panel or parameter unit.
Used to place only the heat generating section of the inverter in
the back of the control box.
By installing this option, the inverter meets the totally enclosed
structure specifications (IP40).
Used to connect a conduit directly.
Mounting plate used to make the mounting dimensions identical to
those of the conventional models.
Noise filer conforming to the EMC Directive (EN50081-2)
……
Used to improve the braking capability of the brake built in the
inverter.
Suppresses surge voltages on the inverter output side.
……
Used to improve the inverter input power factor (overall power
factor about 95%) and cooperate with the power supply.
……
Used to improve the inverter input power factor (overall power
factor about 90%) and cooperate with the power supply.
……
For radio noise reduction
For line noise reduction (applies to small capacities of 3.7kW or
less)
For line noise reduction
Used to improve the braking capability of the inverter (for high-
inertia load or negative load).
Used to improve the braking capability of the inverter (for high-
inertia load or negative load). Use the brake unit and resistor unit
together.
High-function brake unit which can return motor-generated braking
energy to the power supply.
The high power factor converter switches the converter circuit on-
off to convert the input current waveform into a sine wave to
suppress harmonics considerably. (Used with the standard
accessories.)
For independent operation. With frequency meter, frequency
setting potentiometer and start switch.
For joint operation using external signals. (0 to 5VDC, 0 to 10VDC)
(1VA) (Note 2)
For three-speed (high, middle, low) switching operation. (1.5VA)
For remote operation. Allows operation to be controlled from
several places. (5VA)
For ratio control. Allows ratios to be set to five inverters. (3VA)
198
OPTIONS
Applicable
Inverter
Common to
all models
1.5K to 55K,
according to
capacity
0.4K to 22K,
according to
capacity
30K to 55K,
according to
capacity
0.4K to 55K,
according to
capacity
0.4 to 55K,
according to
capacity
0.4K to 7.5K,
according to
capacity
0.4 to 55K,
according to
capacity
0.4K to 55K,
according to
capacity
0.4K to 55K,
according to
capacity
Common to
all models
According to
capacity
Common to
all models