120 Spectra 12000 User Guide
5. Select the slot (from Tape Slots box) that holds the media you wish to
eject. Then select a slot in the Entry/Exit Port box.
6. Tap Move.
7. Tap Open/Close. A window pops up asking Open Entry/Exit Port? Tap
OK. This opens the E/E port.
8. Remove the media.
9. Tap Open/Close. A window pops up asking Close Entry/Exit Port? Tap
OK. This closes the E/E port.
Note: To remove all Queued tapes, tap Eject Queued Tapes.
The Library Controller will find all the tapes that have
been queued for eject and move them to the E/E port.
We recommend you use your backup software to move tapes. However,
from the Inventory screen, you can also:
Š
Identify the contents of every slot in the library, and in the E/E port.
Š
Identify the contents of every drive.
Š
Move all tapes from the E/E cartridge packs into the current partition
(using the Bulk Load button).
Š
Move cartridges from the source location (slot or drive) to a
destination you specify (slot or drive). To move tapes, select a
partition and use the +/- buttons to select a cartridge pack. Then
select the tape you wish to move, the move destination, and tap
Move.