Connections of the power supply cable
The figure below shows the connection of the power supply cable.
①
Version with 1 charging point
②
Version with 2 charging points
③
Terminal L1
Figure 6-1 Connection of auxiliary power supply
Connecting the L1, N, PE conductors
First, connect the PE conductor of the power supply cable to the grounding connector:
1. Remove the sheath of the power supply cable to approximately 8 cm in length.
2. Select the wire end ferrules for the appropriate conductor cross-section.
3. Strip the ends of the conductors so that the remaining insulation reaches up to the wire
end ferrule.
4. Crimp the wire end sleeves properly on the conductor ends.
5. Insert the conductors with wire end ferrules into the correct terminals according to the
electrical circuit diagram.
6. Check the connection of the conductors to the terminals.
Attaching the power supply cable
Secure the power supply cable for the auxiliary power supply after connecting it to the cable
duct.
Dispenser
Operating Instructions, 07/2023, A5E52329862-AB
6.1 Cable for connecting the auxiliary power supply
④
N terminal
⑤
PE ground connection
⑥
Loop through for daisy chain
Connecting
63