Internal design
Design with 1 charging point
The figure below shows the internal structure of the Dispenser Generation 2 with 1 charging
point.
The figure shows the mounting variants on the floor with many options. The design is
identical for wall mounting and ceiling mounting.
①
②
③
④
⑤
⑥
1
= Option
Figure 3-4 Internal design, 1 charging point
30
PLC gateway
Industrial power supply unit 230 V AC / 24 V
DC
Miniature circuit breakers
Ethernet switch
Thermostat
Industrial power supply unit 230 V AC / 48 V
DC
⑦ Control cabinet heater
⑧ DC contactors
⑨ DC fuses
⑩ LED display
⑪ Siemens controller
1
⑫ RFID reader
Operating Instructions, 07/2023, A5E52329862-AB
Dispenser