The following figure shows the minimum clearances for wall/ceiling mounting in the front
view.
Figure 4-6 Minimum clearances for wall/ceiling mounting front view
4.2.4
Maximum permissible temperature
The dispenser is designed for operation at a maximum ambient temperature of +45 °C. A
temperature sensor monitors the internal temperature of the dispenser. If the temperature is
too high, the maximum output power/output current is reduced. In extreme cases, the
charging process is stopped or prevented from starting.
Dispenser
Operating Instructions, 07/2023, A5E52329862-AB
Application planning
4.2 Location planning
45