Configuring The Serial Port - IBM IntelliStation R Pro Hardware Maintenance Manual

Table of Contents

Advertisement

Gateway Type your network gateway router.
Host Name
Type the IP hostname of the Remote Supervisor Adapter. The default
hostname is ASMA<burned-in MAC address>.
For detailed information about the Ethernet settings, see the IBM Remote
Supervisor Adapter User's Guide for the xSeries 330.
7.
You must change the DHCP Setting field to Disabled. The default value is
Enabled.
8.
Press F6 to apply the change.
9.
Press Esc. In the Warning window that opens, press Enter to restart the Remote
Supervisor Adapter.
10. Press Esc to return to the Configuration Settings window.
11. If you need to configure the serial port, go to "Configuring the serial port";
otherwise continue with step 12.
12. Press Esc to return to the Utility program main window.
13. Use the arrow keys to select Exit Utility from the menu or press Esc to close the
Utility program.
14. Remove the CD from the CD-ROM drive. The Remote Supervisor Adapter
restarts automatically.
Continue with "Completing the installation" on page 76.

Configuring the serial port

To configure the Remote Supervisor Adapter serial port for access using a modem or
null modem, complete the following steps:
1.
If you completed the procedure for configuring the Ethernet port and the
Configuration Settings window is open, go to step 5; otherwise, continue with
step 2.
2.
Turn on the server.
3.
Insert the IBM Remote Supervisor Adapter Support CD into the CD-ROM drive and
close the CD-ROM drive before the server completes POST. The CD starts
automatically and the IBM Remote Supervisor Utility window opens.
Note: If you do not insert the CD and close the CD-ROM drive before POST
completes, you must restart the server with the CD in the CD-ROM drive.
Use the Up Arrown and Down Arrow keys (↑ and ↓) to select Configuration
4.
Settings; then, press Enter. The Configuration Settings window opens.
5.
Use the arrow keys to select Modem Settings; then, press Enter.
The Modem Settings window opens.
Note: The values in the following window are only examples; your settings will
be different.
73