Hardware Installation and Reference Guide
The AP adopts the fan-free design. Therefore, maintain sufficient clearance around
the AP for air circulation.
The AP is advised to work in IEEE 802.3at power supply mode to achieve the best
performance.
If IEEE 802.3af power supply is adopted, the AP can be normally powered on, but
only one stream is available for 2.4 GHz and 5 GHz, and the LAN2 port and USB port
cannot supply power to external devices.
If IEEE 802.3at power supply is adopted, the AP can be normally powered on, but the
LAN2 port and USB port cannot supply power to external devices.
1.4.5
Environment and Reliability
Table 1-8
Standard Compliance
Environment and
Reliability
Temperature
Humidity
Regulatory
compliance
1.5
LED and Button
Note
The LED description applies to both Fit and Fat modes, unless otherwise specified.
RG-SAP885-SP
Operating temperature: –10°C to +50°C (14°F to 122°F)
Storage temperature: –40°C to +70°C (–40°F to +158°F)
At a height between 3000 m (9842.52 ft.) and 5000 m (16404.20
ft.) above the sea level, every time the altitude increases by
m (546
ft.), the maximum temperature decreases by 1°C (1.8°F).
Working humidity: 5% RH to 95% RH (non-condensing)
Storage humidity: 5% RH to 95% RH (non-condensing)
EN 55032, EN 55035, EN 61000-3-3, EN IEC 61000-3-2, EN 301
489-1, EN 301 489-3, EN 301 489-17, EN 300 328, EN 301 893, EN
300 440, FCC Part 15, ETSI EN 303 687, EN IEC 62311, IEC 62368-
1, and EN 62368-1