Pin Nr.
Definition
1
+24 VDC
2
+24 VDC
3 (Note
Summary Fault 1
1)
4
Summary Fault 1
5
Summary Fault 1
6 (Note
Summary Fault 2
2)
7
Summary Fault 2
8
Summary Fault 2
9
Ground
10
Ground
11
External Interlock
Return
12
RF Inhibit
13
External Interlock
14
+15 VDC
15
-15 VDC
MNC-0300-070
EAR EXPORT CONTROLLED: The information contained in this Manual refers or relates to a product that is subject
to the U.S. Export Administration Regulations (EAR). Transfer of data herein by any means to a Foreign Person,
whether in the U.S. or abroad, may require an export license from the U.S. Department of Commerce.
Table 1, Auxiliary Connector Pinouts
Available for external use.
Current limit of 100mA.
Normally Open. Closes when fault occurs.
Normally Closed. Opens when fault occurs.
Common, Fault 1
Common, Fault 2
Normally Open. Closes when fault occurs.
Normally Closed. Opens when fault occurs.
Pin 11 must be connected to Pin 13 to enable
High Voltage ON.
Connect Pin 12 to Pin 9 or Pin 10 to inhibit RF
Output.
Pin 13 must be connected to Pin 11 to enable
High Voltage ON
Monitor Only
Monitor Only.
Note 1: Pins 3,4,5 —Form C contacts. Fault 1, Summary Fault.
Note 2: Pins 6,7,8 — Form C contacts. Fault 2, Summary Fault
(Used for redundant systems).